Rheem electric water heater thermostat
Part: SP11725
Upper or lower thermostat listed in the article's Rheem parts table.
Rheem electric water-heater code guide for ECO trips, high-temperature cutoff, thermostat faults, heating elements, sensors, and reset limits.
Rheem electric water-heater code guide for ECO trips, high-temperature cutoff, thermostat faults, heating elements, sensors, and reset limits.
Parts to price first
Part: SP11725
Upper or lower thermostat listed in the article's Rheem parts table.
Part: SP10862
Heating element cited for E1/E2 style upper or lower element failures.
Rheem electric water heaters — including the Performance, Classic, Marathon, and Hybrid Heat Pump models — don’t use flash codes like gas models. Instead, they communicate faults through a combination of ECO (Emergency Cut Off) trips, high-temperature limit switches, and EcoNet digital display codes.
If your electric Rheem stopped producing hot water, the problem is almost always a tripped reset button, a failed thermostat, or a burned-out heating element. Here’s exactly how to diagnose each one.
Electric water heaters are simpler than gas models — no burner, no gas valve, no flame sensor. The system is just:
When something goes wrong, the heater either trips the ECO (cutting all power to the elements) or fails to energize one of the elements. The result is either no hot water at all, or a limited amount of hot water before the tank goes cold.
| Symptom / Code | Meaning | Severity | DIY Fix? |
|---|---|---|---|
| Red button popped out | ECO tripped — high temperature | High — no hot water | Yes — reset and diagnose cause |
| Lukewarm water, runs out fast | Lower element failed | Medium | Yes — replace element |
| Water way too hot (>140°F) | Upper thermostat stuck or failed | Medium | Yes — replace thermostat |
| No hot water, no reset button pop | Upper element or thermostat failed | High | Yes — test and replace |
| E1 on EcoNet display | Upper element fault | High | Yes — test upper element |
| E2 on EcoNet display | Lower element fault | High | Yes — test lower element |
| E3 on EcoNet display | Sensor fault | High | Yes — replace temperature sensor |
| E4 on EcoNet display | Control board fault | High | Call a tech |
| LOC on EcoNet display | Leak detected | High — water leak | Check for water under heater |
The ECO (Emergency Cut Off) — sometimes called the high-limit switch — is a safety device built into the upper thermostat. If the water temperature at the top of the tank exceeds approximately 180°F, the ECO trips and cuts power to both elements.
If the button stays in: The cause was likely temporary — a thermostat that briefly stuck or a power surge. Monitor the water temperature for the next few hours.
If the button pops again immediately or within a day: You have an underlying issue — proceed to diagnosis below.
The ECO is a safety device, not a diagnostic solution. If it keeps tripping, find and fix the root cause — don’t just keep resetting it.
Even without the ECO tripping, your Rheem electric water heater can overheat in a way that damages components. Signs of overheating:
If the T&P valve is leaking, the water is overheating and expanding past the tank’s safe limit. Check the upper thermostat immediately — it should be cutting power to the upper element when the water at the top reaches the set temperature (typically 120°F to 140°F).
Rheem electric water heaters use two thermostats:
When the upper thermostat fails, both elements are affected:
Test the upper thermostat with a multimeter (continuity):
When the lower thermostat fails, you get limited hot water — the top of the tank is hot but it runs cold quickly.
Test with the same continuity method as the upper thermostat.
Heating elements fail in two ways — both easy to diagnose with a multimeter.
You can replace elements without draining the full tank using a wet element puller, but expect some water spillage. For a complete element replacement kit, look for the right wattage and voltage for your Rheem model — most residential units use 4500W 240V elements.
If your Rheem electric water heater has an EcoNet digital display (ProTerra, Hybrid Heat Pump models), you’ll see actual error codes:
| Code | Meaning | Fix |
|---|---|---|
| E1 | Upper element fault | Test upper element and thermostat |
| E2 | Lower element fault | Test lower element and thermostat |
| E3 | Sensor fault | Temperature sensor (thermistor) out of range — replace sensor |
| E4 | Control board fault | Main control board failed — call a tech |
| LOC | Leak detected | Water detected at the leak sensor — check for water under the heater, check drain valve |
These codes may also appear in the Rheem EcoNet mobile app if your heater has Wi-Fi connectivity.
Open the upper access panel and check the red ECO button. If it’s popped, press it in and monitor. If it stays in and the heater works normally, you may have had a one-time event.
Tripped breaker? Reset it. If it trips again immediately, you likely have a shorted element or damaged wiring inside the heater.
Most electric water heater failures are at the upper thermostat — it’s the one that works hardest.
If the upper is working (hot water at top of tank but goes cold quickly), check the lower:
Sediment buildup at the bottom of the tank insulates the lower element and causes it to overheat and fail prematurely. Drain a few gallons from the tank through the drain valve until the water runs clear. Annual flushing extends element life significantly in areas with hard water.
| Part | Rheem OEM # | Amazon equivalent | Cost |
|---|---|---|---|
| Upper thermostat | SP11725 | Rheem universal thermostat | $12–$25 |
| Lower thermostat | SP11725 (same) | Same thermostat | $12–$25 |
| Upper heating element (4500W) | SP10862 | Rheem 4500W screw-in element | $15–$30 |
| Lower heating element (4500W) | SP10862 (same) | Same element | $15–$30 |
| Element wrench | — | Universal element socket tool | $8–$15 |
| Digital multimeter | — | Basic digital multimeter | $15–$40 |
Call a licensed technician or plumber if:
Average repair cost with a technician: $150–$300 for element or thermostat replacement. Water heater replacement: $800–$1,500 installed.