Bradford White natural gas control valve
Part: 239-48774-00
Gas valve assembly cited when the built-in thermistor has failed open or shorted.
Bradford White code 2 guide for water-heater temperature sensor faults, thermistor wiring, control readings, resets, and replacement checks.
Bradford White code 2 guide for water-heater temperature sensor faults, thermistor wiring, control readings, resets, and replacement checks.
Parts to price first
Part: 239-48774-00
Gas valve assembly cited when the built-in thermistor has failed open or shorted.
Part: 239-48775-00
LP gas valve reference from the parts table; verify fuel type and model plate before ordering.
Part: 200-103187-00
Harness reference when connector pins are corroded, loose, or water damaged.
Tool used to confirm open or shorted thermistor readings before parts replacement.
Bradford White water heaters with the Icon System control flash error codes through the status LED. Error code 2 (two slow flashes) means a temperature sensor fault — the gas control valve’s built-in temperature sensor (thermistor) has failed or gone out of acceptable resistance range.
The heater shuts down as a safety measure. Without a valid temperature reading, the control can’t regulate burner operation. The fix is usually a gas control valve replacement, but you may be able to confirm the diagnosis yourself first.
The Icon System control uses a thermistor inside the gas control valve to measure water temperature at the tank bottom. When the control detects a thermistor reading that’s outside the valid range — typically an open circuit (infinite resistance) or a short circuit (near-zero resistance) — it triggers error code 2.
Models affected: Bradford White gas water heaters with the Icon System gas valve — Defender Safety System, DSI, and FVIR-compliant models manufactured from roughly 2005 to present.
The heater will not operate while this code is active. You’ll have no hot water until the sensor circuit is restored or the control valve is replaced.
| Code | Meaning | Severity | DIY Fix? |
|---|---|---|---|
| 2 flashes (every 3 sec) | Temperature sensor fault — thermistor open or shorted | High | Limited — testing is DIY, replacement usually requires a pro |
| Cause | How common | Fix |
|---|---|---|
| Failed gas control valve thermistor | Most common | Replace gas control valve |
| Loose wiring at gas valve connector | Less common | Re-seat or replace wire harness |
| Corroded connector pins | Occasional (high-humidity areas) | Clean with contact cleaner |
| Control board failure | Rare | Replace gas valve assembly |
The gas control valve on Bradford White water heaters is a sealed assembly. The temperature sensor is embedded inside — you can’t replace it separately. This means error code 2 almost always requires a new gas control valve.
Turn the gas control knob to OFF and back to your temperature setting. Watch the LED on the gas valve.
If the code clears after a power cycle but returns later, the thermistor is intermittently failing — it will need replacement soon.
The gas control valve has a wiring harness that connects to the temperature sensor inside the valve body. On most Bradford White models:
If the pins are clean and the connector is fully seated, proceed to Step 3.
You’ll need a digital multimeter for this test. The temperature sensor (thermistor) should show a specific resistance based on the water temperature at the tank bottom.
OL (open loop) on the multimeter means the thermistor has failed open — the gas valve must be replaced.
Near-zero resistance means the thermistor has shorted — the gas valve must be replaced.
Water intrusion into the gas valve connector is a common cause of error code 2, especially on heaters installed in humid basements or crawl spaces.
If the pins are corroded beyond cleaning, you may need the gas valve wire harness as well.
To be thorough, you can back-probe the incoming harness at the control board end to check continuity all the way through. This is more advanced — skip it if you’re not comfortable working with a multimeter near live gas valve circuitry.
| Part | Bradford White OEM # | Amazon equivalent | Cost |
|---|---|---|---|
| Gas control valve (natural gas) | 239-48774-00 | Universal gas valve for Bradford White | $90–$200 |
| Gas control valve (LP) | 239-48775-00 | Bradford White LP gas valve | $90–$200 |
| Wire harness / connector kit | 200-103187-00 | Replacement harness | $15–$30 |
| Digital multimeter | — | Basic digital multimeter | $15–$40 |
Need help finding your model number? Check the data plate on the front of the water heater near the gas valve. It lists the model and serial number you’ll need to cross-reference parts.
Call a licensed plumber or water heater technician if:
Gas valve replacement cost with a technician: $300–$600 installed, including parts and labor. Compare to a new water heater installed at $900–$1,500.