Bradford White hot surface igniter
Part: 100-113029-00
Igniter OEM number listed for ignition lockout diagnosis.
Bradford White code 4 means ignition lockout. Check gas pressure, igniter, flame sensor, venting, condensate, and control wiring.
Bradford White code 4 means ignition lockout. Check gas pressure, igniter, flame sensor, venting, condensate, and control wiring.
Parts to price first
Part: 100-113029-00
Igniter OEM number listed for ignition lockout diagnosis.
Part: 200-103707-00
Flame sensor part number listed for repeated flame-sense failures.
Part: 239-48774-00
Natural-gas valve number listed in the parts table; gas-valve work is a licensed job.
Part: 200-103708-00
Burner gasket kit listed for burner assembly service.
Bradford White water heaters equipped with electronic ignition and the Icon System control display error code 4 (four slow flashes) when the unit fails to ignite after multiple attempts. This is called ignition lockout — the control has given up trying to light the burner after a set number of tries.
No hot water. The burner won’t fire. But the fix is often simple: a dirty igniter or a partially closed gas valve.
The Icon System control in Bradford White gas water heaters uses a hot surface igniter or spark igniter to light the main burner. The control sequence is: purge, spark, trial for ignition, flame sense. If the control doesn’t detect a flame within the ignition trial period — typically 7 seconds — it retries. After 3 failed attempts, it locks out and flashes error code 4.
Models affected: Bradford White gas water heaters with electronic ignition — Defender Safety System (DSI), high-efficiency, and power-vent models. This does not apply to standing pilot models (those use error code 1 for pilot outages).
The lockout must be manually reset by turning the gas control knob to OFF and back to the desired temperature setting.
| Code | Meaning | Severity | DIY Fix? |
|---|---|---|---|
| 4 flashes (every 3 sec) | Ignition lockout — burner failed to light after multiple attempts | High — no hot water | Yes — usually fixable |
| Cause | How common | Fix |
|---|---|---|
| Gas supply shut off or low pressure | Very common | Check shutoff valve, other gas appliances |
| Dirty or misaligned igniter | Common | Clean igniter with sandpaper, check gap |
| Flame sensor dirty or failed | Common | Clean sensor rod with emery cloth |
| Blocked flue or air intake | Occasional | Clear obstructions, check venting |
| Gas valve failure | Uncommon | Replace gas control valve |
Always start by checking the gas supply — this is the simplest fix and accounts for many lockout calls.
Before doing anything else, try a reset:
If the burner lights and stays lit: The error was likely a temporary gas interruption or wind gust. Monitor for reoccurrence.
If error code 4 returns immediately: Proceed to Step 2.
This is the most overlooked cause of ignition lockout. Confirm gas is reaching the water heater.
A half-closed gas valve is a surprisingly common issue after kitchen renovations, meter work, or gas line installation.
Bradford White electronic ignition systems use either a hot surface igniter (glows red-orange) or a spark igniter (makes clicking sounds).
For hot surface igniter models:
The igniter gap should be approximately 3/16” to 1/4” from the burner surface. Use a feeler gauge to check.
For spark igniter models:
The flame sensor is a metal rod that detects when the burner is lit. If it’s dirty, the control shuts the gas valve even though the burner is firing.
A dirty flame sensor is the #1 cause of repeated ignition lockout on electronic ignition water heaters. This fix alone resolves about 50% of error code 4 cases.
Remove the burner assembly and inspect:
A blocked flue is dangerous — it can cause carbon monoxide to enter your home. If you find a blockage, confirm the issue is cleared before restarting the heater.
If you’ve confirmed gas supply, a working igniter, a clean flame sensor, and a clear flue — the gas control valve itself may be the problem.
Gas valve replacement is a licensed job in most areas.
| Part | Bradford White OEM # | Amazon equivalent | Cost |
|---|---|---|---|
| Hot surface igniter | 100-113029-00 | Bradford White 100-113029-00 igniter | $15–$35 |
| Flame sensor rod | 200-103707-00 | Bradford White 200-103707-00 flame sensor | $10–$25 |
| Gas control valve (Nat gas) | 239-48774-00 | Bradford White 239-48774-00 gas valve | $90–$200 |
| Burner gasket kit | 200-103708-00 | Bradford White 200-103708-00 burner gasket | $8–$15 |
Call a licensed technician if:
Average repair cost with a technician: $150–$350 for igniter or flame sensor replacement. Gas valve replacement: $300–$600 installed.