Bradford White gas water heaters with the Icon System control flash error code 5 (five slow flashes) when the flame sense circuit detects a problem. The burner lit successfully, but the control lost the flame-proving signal or never received it.
This is different from error code 4 (ignition lockout) — the burner actually fired, but the control can’t confirm the flame is present. It shuts the gas valve as a safety precaution.
The flame sense circuit uses a metal rod (the flame sensor) and a small electrical current through the flame to prove combustion is happening. When the burner is lit, flame ions conduct a tiny DC current — typically 2-10 microamps — from the sensor rod to ground. The gas control monitors this current. If it drops below the minimum threshold during operation, the control assumes the flame went out and closes the gas valve.
Models affected: Bradford White gas water heaters with electronic ignition — Defender Safety System (DSI) and power-vent models. Not applicable to standing pilot models.
The burner may have been burning normally for minutes or hours before the error triggers. The heater stops producing hot water immediately when the code appears.
| Code | Meaning | Severity | DIY Fix? |
|---|---|---|---|
| 5 flashes (every 3 sec) | Flame sense circuit fault | High — burner shuts down | Yes — usually just cleaning |
| Cause | How common | Fix |
|---|---|---|
| Dirty flame sensor rod | Very common | Clean with emery cloth or sandpaper |
| Flame sensor not in flame path | Common | Adjust sensor position or bracket |
| Weak ground connection | Occasional | Check ground wire, tank bonding strap |
| Carbon tracking on sensor insulator | Less common | Replace sensor rod |
| Gas control valve circuit failure | Uncommon | Replace gas control valve |
The flame sensor rod is exposed to combustion byproducts every time the burner runs. Over time, a thin layer of carbon and oxidation builds up on the rod surface, insulating it and blocking the microamp flame signal. Cleaning it is the fix about 80% of the time.
Turn the gas control knob to OFF, wait 30 seconds, and turn it back to your temperature setting. If the burner lights but error code 5 returns within a few minutes, the flame sense circuit is the issue.
A burner that runs for a cycle or two before error code 5 appears points to an intermittent sensor issue — the signal degrades as the sensor heats up and oxidation reduces conductivity.
This is the most effective fix and takes about 10 minutes.
A properly cleaned flame sensor should have a bright, even metallic surface with no dark spots or carbon residue.
The flame sensor must be positioned so the burner flame directly contacts the rod. If the bracket is bent or the sensor wasn’t fully seated after cleaning, the signal will be weak.
The flame sensor relies on a good ground path through the tank body and gas piping. A weak ground drops the microamp signal.
If the ceramic insulator has black carbon tracks, replace the sensor — cleaning won’t fix the tracking.
If you have a microamp meter (standard multimeter with a microamp setting):
A reading under 1 μA with a visually clean sensor in the flame path points to a gas control valve circuit failure.
A trick for intermittent error code 5: run the heater with the burner access panel removed. If the code doesn’t appear with the panel off, the issue is air supply or flue gas recirculation, not the sensor itself.
| Part | Bradford White OEM # | Amazon equivalent | Cost |
|---|---|---|---|
| Flame sensor rod | 200-103707-00 | Replacement flame sensor | $10–$25 |
| Gas control valve (Nat gas) | 239-48774-00 | Bradford White gas valve | $90–$200 |
| Emery cloth (for cleaning) | — | Fine emery cloth pack | $5–$10 |
| Digital multimeter (μA) | — | Multimeter with microamp setting | $25–$60 |
Call a licensed technician if:
Average repair cost with a technician: $120–$250 for flame sensor replacement including diagnosis. Gas control valve replacement: $300–$600.