A.O. Smith water heater thermopile
Use for low millivolt flash-code faults after cleaning the pilot and checking draft.
Complete A.O. Smith water heater error code guide. Covers Vertex, Voltex, ProLine tankless, and commercial models with fault codes and technician fixes.
Complete A.O. Smith water heater error code guide. Covers Vertex, Voltex, ProLine tankless, and commercial models with fault codes and technician fixes.
Parts to price first
Use for low millivolt flash-code faults after cleaning the pilot and checking draft.
Match the sensor location and model before replacing for E04, E05, or E06 faults.
Inspect and clean on condensing Vertex-style models before ordering.
Maintenance part for tank life, matched by tank size and thread style.
Match temperature, pressure, and BTU rating when replacing a weeping T&P valve.
A.O. Smith manufactures one of the widest lines of water heating equipment in North America, including the ProLine, Vertex (condensing), Voltex (heat pump), and Effex (high-efficiency gas) series. Error codes vary by model — this guide covers all major A.O. Smith fault codes.
| Code | Description | Common Cause |
|---|---|---|
| E01 | Ignition failure | Gas supply, igniter, flame sensor |
| E02 | Flame signal lost during operation | Gas pressure, flame sensor |
| E03 | Overheat / high temperature limit | Scale, low flow, high setpoint |
| E04 | Cold water inlet sensor fault | Sensor failed or wiring |
| E05 | Hot water outlet sensor fault | Sensor failed or wiring |
| E06 | Flue gas temperature sensor fault | Flue sensor fault |
| E07 | Low water flow | Dirty inlet filter, low pressure |
| E08 | Combustion fan fault | Fan motor or speed sensor |
| E09 | Gas valve fault | Gas valve or wiring |
| E10 | Overheat — high limit trip | Second-level overheat protection |
| E11 | Scale detector alert | Scale buildup in heat exchanger |
Standard ProLine and Craftmaster gas storage heaters use LED flash codes:
| Flash Count | Fault | Action |
|---|---|---|
| 1 flash / 3 sec | Normal — pilot lit | No action needed |
| 2 flashes | Thermopile voltage < 350 mV | Clean thermopile, check draft |
| 3 flashes | Pilot out | Relight — check gas supply |
| 4 flashes | Ignition failure | Check spark, gas, thermocouple |
| 5 flashes | Sensor fault | Temperature sensor issue |
| 6 flashes | Thermal switch open | Scale or high temperature trip |
| 7 flashes | Gas valve fault | Gas valve or wiring issue |
| Code | Description | Action |
|---|---|---|
| E01 | Low refrigerant / compressor fault | Check refrigerant and compressor |
| E02 | High refrigerant pressure | Check condenser coil and fan |
| E03 | Fan motor fault | Check fan motor and capacitor |
| E04 | Ambient temperature out of range | Operating range: 37–120°F |
| E05 | Compressor overload | Check amps and refrigerant |
| E06 | Control board fault | Replace control board |
| HP | Heat pump mode active | Normal display |
| Fault | Description | Action |
|---|---|---|
| E1 | Ignition failure | Gas, igniter, flame sensor |
| E2 | Overheat | Scale buildup — descale unit |
| E3 | Flue blocked / combustion air fault | Check vent and combustion air |
| E4 | Blower fault | Check combustion blower |
| E5 | Gas valve fault | Check valve and gas supply |
Scale buildup is the leading cause in hard water areas:
| Part | Notes |
|---|---|
| Thermopile | Match lead length — most ProLine models use 36” |
| Temperature sensors | NTC thermistor — model-specific |
| Condensate trap | Check and clean on Vertex condensing models |
| Pressure relief valve | Replace if weeping — match BTU rating |
| Anode rod | Replace every 3–5 years — extends tank life |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: A.O. Smith and State Water Heaters are the same products with different labels — parts and service procedures are identical across both brands.
E01 means ignition failure. Check gas supply, igniter spark, flame sensor condition, burner ports, and minimum water flow before replacing parts.
E03 overheat is commonly caused by scale buildup, dirty inlet filter screens, high setpoint, or insufficient flow through the heater.
Two flashes mean thermopile voltage is low. Clean the thermopile, confirm the pilot flame surrounds the tip, check for draft issues, and replace the thermopile if voltage stays low.