APC Back-UPS Pro F01-F09 Fault Codes: Official Meanings, Beep Patterns, and Fixes
The official APC F01-F09 System Fault table for Back-UPS Pro, cross-checked against four Schneider Electric sources. F01 and F02 are the only codes with a published user action; F03-F09 are contact-support faults. Plus beep patterns, the 2-second fault reset, and the exact RBC part number per model.
-
APC Symmetra LX PowerView Alarm Messages: Complete Verified Troubleshooting Reference
Every PowerView display message on the APC Symmetra LX (4-16 kVA) from official APC Operations Manual 990-1546: start-up warnings, module failures, threshold alarms, bypass and general fault messages, each with APC's own corrective action.
-
APC Back-UPS Pro F02 Error (On-Battery Output Short): Causes and the Fix That Works
APC Back-UPS Pro F02 means the UPS detected a short circuit on its output while running on battery. The published fix is load isolation: unplug every device from the Battery Backup outlets, restart, and reconnect one item at a time until the fault returns.
-
Rational SelfCookingCenter Service Codes: SCC WE, Legacy SCC and iCombi Reference (Service 10-121, Sub-Codes, Gas Lockout)
Rational combi service codes taken from the four OEM service references: legacy SCC 2004-2011, SCC whitefficiency, iCombi Pro and iCombi Classic. Service 10-14 water faults, the Service 20.x thermocouple sub-codes, CleanJet Service 25, the Service 28/29 temperature limits most lists get wrong, and the gas Service 140 lockout.
-
Rational Service 140.4 and 140.8: The Gas Lockout Codes That Block Your Combi Oven From Cooking (SCC, iCombi Pro, iCombi Classic)
Service 140.4 warns of repeated gas combustion faults on Rational combi ovens; a third trigger within 72 hours produces Service 140.8 and blocks cooking. The official trigger criteria from TI_2220, the critical gas errors behind it (17/18/22/37/38/42), and the per-series service-menu reset paths.
-
Rational Service 25 Error: CleanJet Water Circulation Fault on SCC and iCombi (Causes and Step-by-Step Fix)
Service 25 on a Rational combi means the CleanJet water circulation check failed: the oven saw no water flow, or the jet never loaded the fan wheel. The OEM check list is water supply, pressure, rack position, hoses, pump and CDS sensor, in that order.
-
SEW-Eurodrive Fault F01 (Overcurrent): Causes, Sub-Codes, and How to Isolate Drive vs Motor vs Cable
SEW-Eurodrive F01 is an overcurrent trip on MOVIDRIVE B and MOVITRAC B. Decode MOVIDRIVE B sub-error codes 0-14, apply the P138 ramp-limit fix, and use one lockout-and-meter session to prove whether the drive, the motor, or the cable is at fault.
-
SEW-Eurodrive Fault F14 (Encoder Error): Sub-Codes 0 and 25-34, Hiperface, Resolver, and X14/X15 Wiring Checks
Decode MOVIDRIVE B fault F14 by sub-code: 25 = X15 encoder past 6542 rpm, 28/29 = RS485 errors on X15/X14, 31-33 = Hiperface, 34 = resolver. Plus the cable, shield, and encoder-type checks that actually clear it.
-
SEW-Eurodrive Fault F31 (TF/TH Sensor Tripped): Motor Thermistor Troubleshooting on MOVITRAC B and MOVIDRIVE B
SEW fault F31 means the motor's TF thermistor or TH thermostat tripped — or the sensor loop is open. How to ohm out the loop, when to jumper X10:1-X10:2 on MOVIDRIVE B, and what P835 controls.
-
SEW-Eurodrive MOVIDRIVE MDX60B/61B Fault Codes: Complete Error List with Sub-Error Codes
Every MOVIDRIVE MDX60B/61B fault code from SEW's official error list, F01 through F199, with sub-error codes, factory fault responses, real causes, and field fixes.
-
Daikin H8 Error Code - Causes & Fix
H8 means DC current sensor fault in the outdoor unit's inverter. Most common fix: replace the outdoor unit inverter PCB board.
-
Yaskawa A1000 VFD AL-29 - Causes & Fix
AL-29 does not exist in Yaskawa A1000 documentation. Likely a misread code (CPF29 control circuit error) or third-party alarm label.
-
ABB ACS580 A3A2 Fault - Causes & Fix
A3A2 means DC link undervoltage: the drive's internal DC bus is too low. Most often a blown input fuse or missing phase.
-
Goodman Heat Pump E5 Error - Causes & Fix
E5 on Goodman heat pumps means low-pressure fault or wiring short (model-specific). Most often a refrigerant leak or pinched wire.
-
Hoshizaki E1 Error Code - Causes & Fix
E1 means the freeze cycle ran too long and timed out. Most often a leaking water inlet valve or low water supply is to blame.
-
Weil-McLain A164 Error Code - Causes & Fix
A164 does not appear in Weil-McLain documentation. Verify the display-it may be A44 (bad temp sensor). Check wiring and reset the boiler.
-
Weil-McLain Boiler A163 Error - Causes & Fix
A163 is not a standard Weil-McLain code. Check your model's display and manual for the exact fault. Often an ignition or sensor issue.
-
Weil-McLain A136 Error - Causes & Fix
A136 error meaning varies by Weil-McLain model. Check your service manual or call a tech. Most common: sensor fault or control issue.
-
Weil-McLain Boiler A115 Error - Causes & Fix
A115 is not a standard Weil-McLain code. Check your model's manual for the exact fault. Most boiler shutdowns trace to ignition or sensor issues.
-
Weil-McLain A110 Error - Causes & Fix
A110 is not a standard Weil-McLain fault code. You likely see A01 (no ignition). Check gas supply, reset the boiler, and verify spark.
-
Electrolux Washer E52 Error - Causes & Fix
E52 means the control isn't receiving motor-speed feedback from the tacho sensor. Most often a failed tachogenerator or loose motor wiring.
-
Electrolux E35 Error Code - Causes & Fix
E35 means the pressure sensor detects water overfill. Most often a stuck inlet valve or blocked pressure hose. Reset first.
-
Electrolux Washer E21 Error Code - Causes & Fix
E21 means the washer isn't draining fast enough. The most common fix: clean the clogged drain filter on the underside of the machine.
-
Kenmore Oven F9 Error Code - Causes & Fix
F9 means door-lock fault during self-clean. Most often a failed door latch assembly. Inspect the lock, reset power, or replace latch.