⚡ Quick Answer

Complete guide to resetting VFD trip codes safely, including ABB, Yaskawa, Allen-Bradley, Danfoss, Siemens, and other major drive brands.

⚡ AT A GLANCEScroll down for full repair guide
What it meansComplete guide to resetting VFD trip codes safely, including ABB, Yaskawa, Allen-Bradley, Danfoss, Siemens, and other major drive brands.
Most likely causeMost vfd faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededDrive cooling fan
Repair intent

Need this fixed instead of diagnosed?

Complete guide to resetting VFD trip codes safely, including ABB, Yaskawa, Allen-Bradley, Danfoss, Siemens, and other major drive brands.

Likely parts to price

Price the common parts before you book service.

Drive cooling fan

Common heat-related VFD and servo-drive failure point.

Keypad operator panel

Useful when the drive display or controls fail.

Braking resistor

Price this on braking, deceleration, and overvoltage faults.

VFD Trip Reset Guide: How to Clear Fault Codes Safely

Resetting a VFD trip is easy. Resetting it safely is the real job. Overcurrent, ground fault, overvoltage, undervoltage, overtemperature, and communication faults all clear in slightly different ways, but the rule is the same: identify whether the trip was caused by the load, the motor, the power source, the setup, or the drive itself before you hammer the reset button.

Jump to Fix

Common VFD Trip Types

Symptom / CodeCommon MeaningTypical Brands
OvercurrentLoad jam, short ramp, or output shortABB, Yaskawa, Allen-Bradley, Danfoss
Ground faultMotor or cable insulation leakAll major VFDs
OvervoltageFast decel or regenerative loadAll major VFDs
UndervoltageLow line voltage or phase lossAll major VFDs
OvertempCooling failure or overloaded driveAll major VFDs
CommunicationPLC / keypad / fieldbus lossNetworked systems

When a simple reset is fine

A nuisance communication glitch or a known utility sag may clear cleanly once. Even then, it is worth checking logs before resuming full production.

When not to reset blindly

Ground fault, repeated hardware overcurrent, and short-circuit style trips should not be reset repeatedly. Those are the faults that destroy replacement drives if the motor or cable is bad.

Best practice sequence

Read the code, review history, isolate motor if needed, verify line power, then reset and monitor. That sequence beats guesswork every time.

Step-by-Step Fix

  1. Capture the fault code and time — Write it down or pull the log before power cycling.
  2. Look for obvious mechanical issues — Jam, seized bearing, blocked conveyor, or overloaded pump first.
  3. Check power and cooling — Undervoltage and overtemp faults often have simple physical causes.
  4. Isolate motor and cable for serious trips — Ground and hardware overcurrent faults demand insulation testing.
  5. Reset through the proper path — Use keypad reset, digital input reset, or PLC reset per the drive design. Avoid random power cycling as your only method.
  6. Monitor after restart — Watch current, temperature, and trip timing during a real load cycle.

Parts and Tools Often Needed

ItemNotes
MegohmmeterEssential for grounding and insulation faults
Clamp meterCheck current draw under load
Cooling fanDrive overtemp issues
Brake resistorNeeded for repeat overvoltage decel trips
Input fusesFor undervoltage and phase-loss issues
Parameter backupAlways save settings before replacing a drive

Need Replacement Parts?

Before ordering, match the drive part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If a VFD keeps tripping on the same code after one informed reset attempt, the reset was never the fix. At that point you need diagnosis, not more resets.


Need a professional? Compare Industrial repair options before replacing parts.