Skip to content
Industrial Error Code Fixes
Go back

ABB ACS150 Micro Drive Fault Codes

⚡ Quick Answer

ABB ACS150 guide for overcurrent, DC bus, short-circuit, overtemperature, phase-loss, motor-stall, overload, and parameter faults.

⚡ AT A GLANCEScroll down for full repair guide
What it meansABB ACS150 guide for overcurrent, DC bus, short-circuit, overtemperature, phase-loss, motor-stall, overload, and parameter faults.
Most likely causeMost vfd faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededDrive cooling fan
Repair intent

Need this fixed instead of diagnosed?

ABB ACS150 guide for overcurrent, DC bus, short-circuit, overtemperature, phase-loss, motor-stall, overload, and parameter faults.

Likely parts to price

Price the common parts before you book service.

Drive cooling fan

Common heat-related VFD and servo-drive failure point.

Keypad operator panel

Useful when the drive display or controls fail.

Braking resistor

Price this on braking, deceleration, and overvoltage faults.

ABB ACS150 Micro Drive Fault Codes — What They Mean

The ABB ACS150 is a compact micro drive built for simple machine control, including conveyors, fans, mixers, and light-duty pumps. It uses ABB’s standard fault structure with a numeric code shown on the keypad display. Because the ACS150 is often installed in small OEM panels with minimal cooling, many of its common faults come from overheating, wiring mistakes, and parameter issues rather than true hardware failure.

Jump to Fix

ABB ACS150 Common Fault Code Reference

Fault CodeMeaning
0001Overcurrent
0002DC overvoltage
0003DC undervoltage
0004Short circuit
0005Overtemperature
0006Output phase loss
0007Motor stall
0008Motor overload
0009Panel communication fault
0010AI1 analog input loss
0012External fault
0016Earth fault
0018Internal control fault

Common Causes by Fault

Step-by-Step Fix

  1. Read the displayed fault code — Record the number before resetting.
  2. For 0001 or 0007 — Disconnect the mechanical load if possible and test the motor free-running. Increase acceleration time.
  3. For 0005 — Clean vents, confirm fan operation, and verify enclosure temperature is within spec.
  4. For 0016 — Megger the motor and cable to ground with the drive disconnected.
  5. Reset and monitor — After correcting the issue, reset the drive and confirm it runs through a full cycle.

Parts Often Needed

PartNotes
Cooling fanCommon wear item in hot panels
Keypad panelFor display or navigation issues
Complete ACS150 driveFor persistent internal faults
Motor cableReplace if insulation is damaged

Need Replacement Parts?

Before ordering, match the drive part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If the ACS150 repeatedly throws 0018 internal control faults or trips immediately with the motor disconnected, the drive has likely failed internally. ABB support or an industrial drive specialist should confirm replacement rather than continued resets.


Need a professional? Compare Industrial repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
ABB ACS355 Fault Codes - Complete Drive Troubleshooting Guide
Next Post
ABB ACS880 PLC Integration Fault Codes