Drive cooling fan
Common heat-related VFD and servo-drive failure point.
ABB ACS355 fault code guide covering 2310, 2330, 3130, 3180, 3210, 3220, 4110, 7121, and common machinery drive faults.
ABB ACS355 fault code guide covering 2310, 2330, 3130, 3180, 3210, 3220, 4110, 7121, and common machinery drive faults.
Likely parts to price
Common heat-related VFD and servo-drive failure point.
Useful when the drive display or controls fail.
Price this on braking, deceleration, and overvoltage faults.
The ABB ACS355 is a machinery drive used on conveyors, pumps, fans, mixers, and OEM equipment. ACS355 fault codes identify the protection function that stopped the drive. The fastest path is to separate supply faults, motor/cable faults, thermal faults, and internal drive faults before replacing parts.
| Code | Meaning | First Check |
|---|---|---|
| 2310 | Overcurrent | Jammed load, shorted motor cable, fast acceleration |
| 2330 | Earth fault | Motor insulation and cable damage |
| 2340 | Short circuit | Motor leads and output terminals |
| 2381 | IGBT overload | Motor cable, switching stress, output fault |
| 3130 | Input phase loss | Input fuses, missing phase, voltage imbalance |
| 3180 | Charge relay lost | Internal charge circuit or relay feedback |
| 3181 | Cross connection | Input and motor leads wired to wrong terminals |
| 3210 | DC bus overvoltage | Decel ramp, regen load, braking resistor |
| 3220 | DC bus undervoltage | Incoming supply, contactor, line sag |
| 4110 | Drive overtemperature | Cooling fan, heatsink, cabinet heat |
| 7121 | Motor stall | Locked load, wrong motor data, torque limit |
Fault 3130 means input phase loss. Start with the upstream fuses, then measure L1-L2, L2-L3, and L1-L3 at the drive. If one phase is low or missing, fix the supply before resetting the drive.
| Part | Notes |
|---|---|
| Input fuses | Common cause of 3130 |
| Motor cable | Common cause of 2330 and 2340 |
| Cooling fan | Common cause of 4110 in dusty cabinets |
| Braking resistor | Helps with 3210 during fast deceleration |
| Replacement ACS355 | Consider for 3180 or repeat output faults with motor disconnected |
Before ordering, match the drive part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Call a qualified electrician or drive technician for any fault that requires live three-phase measurement, insulation testing, or internal drive diagnosis. Stored DC bus voltage inside the ACS355 can remain dangerous after power is removed.