Skip to content
Industrial Error Code Fixes
Go back

More industrial fault codes

VFD Fault Code Lookup: All Brands

⚡ Quick Answer

Master VFD fault code lookup guide covering ABB, Danfoss, Siemens, Schneider, Mitsubishi, Yaskawa, Allen-Bradley, and more.

⚡ AT A GLANCEScroll down for full repair guide
What it meansMost VFD faults, whatever the brand, reduce to overcurrent, overvoltage, undervoltage, overtemperature, ground fault, communication loss, or motor feedback issues.
Most likely causeMechanical bind, cable short, or a ramp set too fast; decel too fast or a regenerative load; supply loss; cooling failure or hot enclosure; motor or cable insulation breakdown; PLC, fieldbus, or keypad network issues.
First checkCapture the exact code and whether it happened during accel, run, decel, or idle, then confirm the load turns freely and incoming power quality is acceptable before touching parameters.
⏱Repair time30-60 minutes to classify the fault and complete hardware checks before moving to the brand-specific guide
🔧Part neededCooling fan, braking resistor, keypad or HMI, replacement drive

Parts to price first

Check the part before you book service.

VFD cooling fan

Frequent source of thermal faults; match voltage and frame size.

VFD braking resistor

Needed for fast-stop or regenerative applications that trip overvoltage.

VFD keypad / HMI

For local diagnostics when the drive keypad or network link is the fault.

Replacement VFD

For confirmed internal hardware faults; match voltage, horsepower, and enclosure rating.

Equipment service manual download (eManualOnline)

The full OEM-style workshop manual has the wiring diagram, test values, and the fault table this guide summarizes. Instant PDF download.

Repair intent

Need this fixed instead of diagnosed?

Master VFD fault code lookup guide covering ABB, Danfoss, Siemens, Schneider, Mitsubishi, Yaskawa, Allen-Bradley, and more.

VFD Fault Code Lookup — Start Here

Variable frequency drive faults look brand-specific on the screen, but most of them reduce to a small set of root causes: overcurrent, overvoltage, undervoltage, overtemperature, communication loss, and motor feedback issues. This page helps technicians classify the fault before going to the drive-specific guide.

Jump to Fix

Common VFD Fault Patterns

Fault TypeWhat It Usually Means
OvercurrentMechanical bind, cable short, ramp too fast
OvervoltageDecel too fast, regenerative load
UndervoltageSupply loss or weak incoming power
OvertemperatureCooling failure or hot enclosure
Ground faultMotor or cable insulation breakdown
Communication faultPLC, fieldbus, or keypad/network issue

Brands Covered

Step-by-Step Fix

  1. Capture the exact code and operating state — accel, run, decel, or idle.
  2. Separate load issues from drive issues — Can the motor/load turn freely?
  3. Check incoming power quality.
  4. Inspect motor cable, grounding, and enclosure cooling.
  5. Review parameters only after hardware basics are verified.

Parts Often Needed

PartNotes
Cooling fanFrequent source of thermal faults
Braking resistorNeeded for fast-stop applications
Keypad / HMIFor local diagnostics
Replacement driveFor confirmed internal hardware faults

Need Replacement Parts?

Before ordering, match the drive part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If the drive faults with the motor disconnected, or if you see repeated hardware or DC bus faults, involve a qualified drive technician. Parameter guessing and repeated resets can make a controllable problem much more expensive.

Looking up a different drive? Try the VFD fault code lookup tool.

Quick FAQ

Why do VFD fault codes look different across brands?

Each manufacturer uses its own code numbering, but the root causes are the same small set: overcurrent, overvoltage, undervoltage, overtemperature, ground fault, communication loss, and motor feedback issues. Classify the fault type first, then go to the brand-specific guide.

What usually causes a VFD overcurrent fault?

A mechanical bind on the load, a short in the motor cable, or an acceleration ramp set too fast. Check whether the motor and load turn freely before adjusting parameters.

What causes a VFD overvoltage fault?

Decelerating too fast or a regenerative load pushing energy back into the DC bus. Fast-stop applications often need a braking resistor.

What is the first step when a VFD faults?

Capture the exact code and the operating state (accel, run, decel, or idle). Then separate load issues from drive issues, check incoming power quality, inspect the motor cable, grounding, and enclosure cooling, and only then review parameters.

When should I call a drive technician?

If the drive faults with the motor disconnected, or you see repeated hardware or DC bus faults. Parameter guessing and repeated resets can make a controllable problem much more expensive.


Need a professional? Compare Industrial repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
ABB ACS580 Fault 3130 - Input Phase Loss Fix
Next Post
ABB ACS550 Fault Codes: Complete Diagnostic Guide