Cooling fan
Common VFD, drive, UPS, and cabinet overheating failure point.
Diagnose Schneider Altivar Fault CFF - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Common VFD, drive, UPS, and cabinet overheating failure point.
Useful to price when faults involve display, keypad, or operator-panel behavior.
Low-cost first check for power-stage and line-side faults.
Price this on drive overvoltage, braking, or deceleration faults.
The full OEM-style workshop manual has the wiring diagram, test values, and the fault table this guide summarizes. Instant PDF download.
Diagnose Schneider Altivar Fault CFF - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Schneider Altivar fault CFF (Configuration Fault) indicates an incorrect configuration was detected — the drive found a mismatch or incompatibility between the stored configuration data and the drive’s current hardware or software. CFF is common on Altivar 12, 21, 31, 61, and 71 series drives and typically appears after a firmware update, parameter restore, or option card change that results in conflicting or incomplete parameter data. The drive refuses to run until the configuration is resolved.
[Full] menu → [FCS] → Set to [InI] → Confirm.| Part | Notes |
|---|---|
| No hardware typically needed | CFF is almost always a configuration/software issue |
| Option card | Only if the installed card is damaged or wrong type |
Before ordering, match the drive part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If CFF persists after a factory reset, the drive’s internal parameter EEPROM may be corrupted. Schneider Electric’s repair centers can reflash the drive firmware and restore the parameter memory. Contact Schneider service if factory reset doesn’t resolve the fault.