Thermocouple
Common pilot and ignition part on gas water heaters.
Troubleshoot Rinnai 25 on boilers and tankless water heaters with checks for gas, venting, sensors, pumps, ignition, and service limits.
Troubleshoot Rinnai 25 on boilers and tankless water heaters with checks for gas, venting, sensors, pumps, ignition, and service limits.
Likely parts to price
Common pilot and ignition part on gas water heaters.
Price this on no-light and ignition failure symptoms.
Common fault-code part. Confirm model and sensor style first.
Higher-cost part to price after confirming supply, venting, and ignition checks.
Rinnai error code 25 means the thermal fuse or overheat cutoff has activated. Rinnai tankless water heaters include a one-shot thermal fuse — a sacrificial device that permanently opens if the unit’s internal temperature reaches a dangerous level. Unlike auto-reset safety devices, the thermal fuse is a physical component that must be replaced once it trips. Code 25 is not a transient fault; the unit is locked out and will stay locked out until the thermal fuse is physically replaced. Overheating is almost always caused by a venting restriction that traps combustion heat inside the unit.
| Part | Notes |
|---|---|
| Thermal fuse (one-time trip) | Model-specific; Rinnai part number stamped on old fuse — must match |
| Vent termination cap (Rinnai-approved) | Replace if blockage was in the cap |
| Vent pipe (3” or 4” PVC schedule 40) | Reroute if run length exceeded spec |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
A thermal fuse that blows again shortly after replacement means the root cause wasn’t fully corrected. A Navien-certified tech (or Rinnai service tech) can do a combustion analysis and verify vent performance with proper instruments.