Thermocouple
Common pilot and ignition part on gas water heaters.
Troubleshoot Rinnai error code 14 on boilers and tankless water heaters with checks for gas, venting, sensors, pumps, ignition, and service limits.
Likely parts to price
Common pilot and ignition part on gas water heaters.
Price this on no-light and ignition failure symptoms.
Common fault-code part. Confirm model and sensor style first.
Higher-cost part to price after confirming supply, venting, and ignition checks.
Elements, thermostats, thermocouples, gas valves, and anode rods in stock when the local supply house is closed.
Troubleshoot Rinnai error code 14 on boilers and tankless water heaters with checks for gas, venting, sensors, pumps, ignition, and service limits.
Rinnai error code 14 indicates the thermal fuse (or flue thermal fuse) has opened. The thermal fuse is a one-time, non-resettable safety device positioned in the flue gas path. It opens permanently if flue gas temperatures exceed its rating — typically 167°F (75°C) for the case thermal fuse or higher for the combustion chamber version. Once it opens, the unit will not fire until the thermal fuse is replaced. This fault almost always indicates that an abnormal heat condition existed in the flue path: restricted exhaust, very high firing rates, a blocked heat exchanger, or recirculating exhaust gases.
| Part | Notes |
|---|---|
| Thermal fuse (case or combustion type) | Non-resettable; must be replaced; match temperature rating and model number |
| Descaling kit (citric acid) | Use if scale is confirmed cause; prevents recurrence |
| Vent pipe section or cap | Replace damaged sections contributing to exhaust blockage |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the thermal fuse opens again within a short period after replacement, the combustion system or venting has a fundamental problem. Combustion analysis, heat exchanger inspection, and vent design review require a licensed plumber or HVAC technician.