Thermocouple
Common pilot and ignition part on gas water heaters.
Diagnose Rinnai Error Code 16 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Diagnose Rinnai Error Code 16 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Common pilot and ignition part on gas water heaters.
Price this on no-light and ignition failure symptoms.
Common fault-code part. Confirm model and sensor style first.
Higher-cost part to price after confirming supply, venting, and ignition checks.
Error code 16 on a Rinnai tankless water heater indicates the combustion fan (also called the exhaust blower or induced draft fan) is not operating within the expected speed range. The control board monitors fan RPM via a Hall effect sensor on the fan motor. If the fan runs too slow, too fast, or not at all, code 16 is displayed and the unit shuts down — without confirmed fan operation, the board will not open the gas valve.
| Part | Notes |
|---|---|
| Combustion fan motor assembly | Rinnai OEM; must match model (V-series vs. RU-series differ) |
| Fan speed sensor | Hall effect sensor; often integral to the motor assembly |
| Control board (PCB) | Replace only if board fan driver is confirmed failed |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Gas appliance fan replacement involves working inside the combustion enclosure. If you are not confident in safely accessing the combustion section and verifying electrical circuits, have a Rinnai-authorized technician service the unit.