Skip to content
Industrial Error Code Fixes
Go back

Rinnai Error Code 33 — Causes & Fix

⚡ Quick Answer

Diagnose Rinnai Error Code 33 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.

⚡ AT A GLANCEScroll down for full repair guide
What it meansDiagnose Rinnai Error Code 33 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Most likely causeMost boiler faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededThermocouple
Repair intent

Need this fixed instead of diagnosed?

Diagnose Rinnai Error Code 33 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.

Likely parts to price

Price the common parts before you book service.

Thermocouple

Common pilot and ignition part on gas water heaters.

Igniter

Price this on no-light and ignition failure symptoms.

Temperature sensor

Common fault-code part. Confirm model and sensor style first.

Gas valve

Higher-cost part to price after confirming supply, venting, and ignition checks.

Rinnai Error Code 33 — What It Means

Rinnai error code 33 indicates exhaust overheat — the flue exhaust temperature exceeded safe limits as measured by the exhaust thermistor. Rinnai tankless water heaters monitor outgoing flue gas temperature to ensure the venting system isn’t overheating. Code 33 trips when the exhaust temperature rises above approximately 230°F (110°C), which can indicate a combustion problem, blocked exhaust, or heat exchanger scale buildup that’s concentrating heat in the exhaust rather than transferring it to the water.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Inspect the exhaust vent termination — Go to where the vent exits the building. Confirm the terminal cap is unobstructed (no bird nests, ice, or debris). For concentric vents, check both the exhaust and air intake openings.
  2. Check combustion air supply — If the unit is in a closet or equipment room, confirm there is adequate makeup air per the installation manual. A small, sealed room can starve combustion air.
  3. Descale the heat exchanger — Connect a descaling pump and circulate a citric acid or white vinegar solution through the heat exchanger service ports for 30–60 minutes. Flush thoroughly with water after descaling.
  4. Clean the burner assembly — A dirty burner produces uneven combustion. Inspect and clean the burner per the Rinnai service manual; this typically requires removing the burner assembly.
  5. Test the exhaust thermistor — With power off, disconnect the exhaust sensor and measure resistance. Compare to Rinnai’s sensor specification. Out-of-spec = replace the sensor.
  6. Reset the unit — Press the on/off button twice or cut power at the disconnect for 30 seconds. Restore and run a hot water draw to verify code 33 is cleared.

Parts Often Needed

PartNotes
Exhaust temperature thermistorRinnai model-specific; verify part number for your series (V, RU, or RL)
Descaling kitPump + citric acid; available from Rinnai dealers
Vent terminal capReplace if damaged or blocked by animal activity

Need Replacement Parts?

Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If descaling and vent inspection don’t resolve code 33, have a technician measure actual combustion air/fuel ratio (CO₂ or O₂ levels) with a combustion analyzer. Persistent exhaust overtemperature with clean heat exchanger can indicate a gas pressure or valve modulation problem requiring licensed service.


Need a professional? Compare Water heater repair options before replacing parts.