Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Lennox XC16 guide for iComfort alerts, high/low pressure faults, fan errors, compressor protection, sensor faults, and board checks.
Lennox XC16 guide for iComfort alerts, high/low pressure faults, fan errors, compressor protection, sensor faults, and board checks.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Lennox XC16 is a 16–21 SEER2 two-stage central air conditioner that uses the iComfort S30 or compatible communicating thermostat when installed in a full Dave Lennox Signature system. It communicates faults both through the thermostat display (when in communicating mode) and through a diagnostic LED on the outdoor unit board. The XC16 uses R-410A and features a two-stage scroll compressor for improved efficiency and dehumidification at part load.
| Alert Code | Meaning |
|---|---|
| 103 | High-pressure switch open |
| 111 | Low-pressure switch open |
| 114 | Loss of charge — pressure too low |
| 125 | Outdoor fan motor fault |
| 204 | Compressor protection — thermal overload |
| 223 | Discharge temperature sensor fault |
| 225 | Outdoor ambient sensor fault |
| 231 | Communication fault — outdoor board |
| 327 | High-stage compressor fault |
| 332 | Contactor fault detected |
| 411 | Control board hardware fault |
| Part | Notes |
|---|---|
| Dual run capacitor | Compressor and fan; most common single failure |
| Contactor | Two-pole; check for pitting and coil resistance |
| Condenser fan motor | Match HP, RPM, frame size |
| High-pressure switch | 610 PSIG cutout for R-410A |
| Low-pressure switch | 50 PSIG cutout; replace if code persists |
| Outdoor communication board | For Alert 231 or 411 |
For XC16 air-conditioner faults, diagnose the outdoor unit first: condenser coil condition, fan motor, capacitor, contactor, pressure switches, line-voltage supply, and the outdoor control board.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
The XC16’s two-stage compressor makes refrigerant charging more complex than a single-stage unit — the system must be checked at both low-stage and high-stage operation to confirm correct superheat and subcooling. Lennox requires iComfort-enabled service tools for advanced diagnostics. Contact a Lennox Premier Dealer for communicating system issues beyond basic troubleshooting.