Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Troubleshoot Lennox 103 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Lennox 103 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Lennox error code 103 indicates a pressure switch fault — the iComfort or SureLight control board did not detect the pressure switch closing during the draft motor startup sequence. The furnace tries to prove inducer operation before allowing ignition, and when the pressure switch won’t confirm airflow, the ignition sequence is blocked. On Lennox iComfort systems, code 103 appears on the thermostat display; on older SureLight boards it flashes on the LED. The cause is almost always mechanical — blocked flue, clogged condensate, or a failed draft motor — not the switch itself.
| Part | Notes |
|---|---|
| Induced draft motor | Model-specific; Lennox uses several suppliers across product lines |
| Draft motor capacitor | Cheap fix if motor won’t start; test before replacing motor |
| Pressure switch | Match the WC rating printed on the old switch |
| Condensate trap | Replacement traps are model-specific on Lennox 90%+ units |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the draft motor is running at speed, vents are clear, and condensate drains freely, but code 103 persists, a tech should measure static pressure with a manometer to determine whether the switch rating matches actual system pressure.