Troubleshoot Lennox error code 111 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Lennox error code 111 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Lennox fault code 111 (three flashes on the diagnostic LED, or displayed as “111” on SureLight boards) indicates the rollout switch has opened. The rollout switch is a thermal fuse-type safety device positioned near the burner orifices or heat exchanger opening. It trips when combustion gases or flame exit the heat exchanger in an uncontrolled direction — a condition called flame rollout. This is a hard safety event: the furnace shuts down completely and will not restart until the switch is manually reset and the root cause is addressed.
| Part | Notes |
|---|---|
| Rollout limit switch | Verify correct temp rating — Lennox uses several setpoints |
| Induced draft motor with wheel | Replace as assembly if wheel is cracked or motor bearing is worn |
| Vent pipe elbow or section | Replace cracked or blocked PVC sections on 90%+ units |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Flame rollout combined with a cracked heat exchanger is a carbon monoxide hazard. If you cannot identify a clear venting or draft cause for the rollout trip, stop operating the furnace and have a technician perform a full combustion and heat exchanger inspection before restart.