Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Lennox G60UHV furnace flash-code guide for inducer speed, pressure switches, high-limit trips, SureLight ignition, blower faults, and boards.
Lennox G60UHV furnace flash-code guide for inducer speed, pressure switches, high-limit trips, SureLight ignition, blower faults, and boards.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Lennox G60UHV is a variable-speed, 80% AFUE gas furnace that uses an ECM blower motor for quiet, efficient operation. It reports faults through a flashing LED on the control board (SureLight integrated furnace control). The LED flashes a code number, pauses, then repeats. The G60UHV also supports Lennox iComfort and Harmony III communicating thermostat systems, which can display readable fault descriptions.
| Flash Code | Meaning |
|---|---|
| 1 flash | Normal — call for heat satisfied |
| 2 flashes | Inducer motor not at speed |
| 3 flashes | Pressure switch stuck open |
| 4 flashes | High-limit switch open |
| 5 flashes | Flame sensed — no call for heat |
| 6 flashes | AC power fault (115V) |
| 7 flashes | Gas valve circuit fault |
| 8 flashes | Ignition lockout (failed to prove flame) |
| 9 flashes | Rollout limit switch open |
| 10 flashes | Pressure switch stuck closed |
| 11 flashes | Blower motor fault |
| 12 flashes | Limit device fault (repeated trips) |
| 13 flashes | Control board failure |
| Part | Notes |
|---|---|
| SureLight ignitor | Lennox-specific; use OEM part number |
| Condensate trap | Integrated into G60UHV cabinet; replace if cracked |
| ECM blower module | Mounts to rear of motor; test before replacing motor |
| Pressure switch | Confirm correct rating for single or two-stage |
| Inducer motor | Replace bearing or full motor assembly |
| Control board | For Code 13 or communication errors |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
The G60UHV’s ECM motor requires specialized diagnosis. Lennox sells a motor tester tool (L0409MOTORTOOL) used by authorized dealers to identify whether the fault is in the motor, module, or control board. If you’re seeing Code 11 or 13 without an obvious cause, an authorized Lennox dealer can connect diagnostic tools for a definitive diagnosis.