Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Lennox Elite furnace guide for SureLight flash codes, iComfort alerts, pressure switches, rollout trips, ignition faults, and blower errors.
Lennox Elite furnace guide for SureLight flash codes, iComfort alerts, pressure switches, rollout trips, ignition faults, and blower errors.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Lennox Elite Series includes several residential gas furnace models: the EL195E, EL180E, EL296V, and G61MPV among others. These furnaces use Lennox’s SureLight control board system, which reports faults through a status LED (flash codes) on non-communicating models or through three-digit alert codes on iComfort-enabled systems. Elite Series furnaces range from 80% to 96% AFUE and include single-stage, two-stage, and variable-speed variants.
| Flash Code | Alert Code | Fault |
|---|---|---|
| 2 flashes | 111 | Pressure switch stuck open |
| 3 flashes | 112 | Pressure switch stuck closed |
| 4 flashes | 223 | Open high-limit device |
| 5 flashes | 224 | Rollout switch open |
| 6 flashes | 225 | Flame not established at end of trial |
| 7 flashes | 411 | Ignition lockout — 3 retries failed |
| 8 flashes | 412 | Flame sensed without gas valve call |
| 9 flashes | 414 | Low gas pressure |
| 10 flashes | 431 | Communication fault (iComfort) |
| 11 flashes | 432 | Blower fault |
| 12 flashes | 434 | Inducer motor fault |
| Rapid | 540 | Control board fault |
| Part | Notes |
|---|---|
| SureLight igniter | Silicon nitride; part number varies by model |
| Flame sensor | Clean with fine steel wool; measure µA output |
| Pressure switch | Single or dual switch depending on model |
| ECM blower motor module | Replace module only if motor spins freely |
| High-limit switch | Check reset button — some are auto-reset, some manual |
| Rollout switch | Manual-reset; do not bypass |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Lennox Elite Series furnaces with iComfort communicating systems require Lennox service tools for full diagnostics. Alert Code 540 (control board fault) and any code that returns after a verified repair should be evaluated by a Lennox Premier Dealer. Heat exchanger inspection for rollout switch trips requires camera inspection equipment and combustion analysis.