Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Lennox furnace error codes: all fault codes for G61, ML, EL, and SL series furnaces with causes and fixes.
Lennox furnace error codes: all fault codes for G61, ML, EL, and SL series furnaces with causes and fixes.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Lennox furnaces use a combination of flash codes (older models) and numeric fault codes displayed on an iComfort thermostat or the control board’s diagnostic port (newer communicating models). On non-communicating furnaces, look for the blinking LED on the IFC board through the lower access panel. Lennox also makes Aire-Flo, Armstrong Air, and Ducane — codes may overlap.
| Code | Meaning | Quick Fix |
|---|---|---|
| 103 | Rollout switch lockout | Inspect heat exchanger; reset switch |
| 111 | No previous fault | Normal after power cycle |
| 114 | Blower on/off delay | Timing fault; check blower |
| 125 | Pressure switch fault | Check inducer, hose, drain trap |
| 204 | Ignition lockout | Check gas, igniter, flame sensor |
| 223 | Limit switch open | Clean/replace filter; check blower |
| 225 | Flame roll-out switch open | Safety fault; inspect heat exchanger |
| 231 | Gas valve fault | Gas valve or wiring issue |
| 327 | Pressure switch stuck closed | Check pressure switch hose |
| 332 | Inducer motor fault | Check inducer motor and wiring |
| 411 | Flame sensed without call | Possible gas valve leak |
| 412 | Flame failure | Clean flame sensor; check gas |
| 414 | Gas valve or roll-out fault | Check gas valve energization |
| 432 | Communication fault | Check thermostat wiring |
| 434 | Blower motor fault | Check motor and capacitor |
| 540 | Board fault | Replace IFC board |
| 292 | Variable-speed blower fault | Check blower motor ECM |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Four ignition attempts failed. On Lennox G61MPV and ML296V models, check the hot-surface igniter — Lennox uses a silicon nitride igniter rated at 40–90 ohms cold resistance. Also verify the gas supply is on and check the main gas valve operator coil for continuity (24V AC signal should reach the valve on a call for heat).
Limit switch tripped due to overheating. Replace the filter first — Lennox high-efficiency models use thick media filters that clog quickly. Also verify all supply and return registers are open. On variable-speed models (ML/EL/SL series), check that the ECM blower motor ramps up properly; a failing motor running at low speed causes repeated limit trips.
Hot gases backed out of the heat exchanger and melted a fuse link or tripped a manual-reset roll-out switch. This is a serious fault — do not simply reset without finding the cause. Possible causes: blocked flue pipe, cracked heat exchanger, excessive gas pressure, or blocked secondary heat exchanger on 90%+ models.
Burner lit briefly but flame wasn’t confirmed. Clean the flame sensor rod. On Lennox G61 series, the flame sensor is located in the rightmost burner position. Microamp signal should be above 1.5 µA; below 1.0 µA is unreliable.
On iComfort-equipped systems, the furnace and thermostat have lost the communication bus. Check the 2-wire thermostat cable and connections at both ends. A short in the communication wire is common if rodents have accessed the unit.
The ECM blower motor on variable-speed Lennox furnaces has reported a fault. This can mean a failed motor, bad motor controller module, or communication error between the board and ECM. Start by checking all harness connectors to the motor.
Codes 225 (roll-out) and 411 (flame without call) require professional inspection before the furnace is restarted. A cracked heat exchanger or leaking gas valve are not DIY repairs.