Lennox Furnace Error Codes — Complete Reference Guide

⚡ Quick Answer

Lennox furnace error codes: all fault codes for G61, ML, EL, and SL series furnaces with causes and fixes.

⚡ AT A GLANCEScroll down for full repair guide
What it meansLennox furnace error codes: all fault codes for G61, ML, EL, and SL series furnaces with causes and fixes.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Lennox furnace error codes: all fault codes for G61, ML, EL, and SL series furnaces with causes and fixes.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Lennox Furnace Error Codes — Quick Reference

Lennox furnaces use a combination of flash codes (older models) and numeric fault codes displayed on an iComfort thermostat or the control board’s diagnostic port (newer communicating models). On non-communicating furnaces, look for the blinking LED on the IFC board through the lower access panel. Lennox also makes Aire-Flo, Armstrong Air, and Ducane — codes may overlap.

CodeMeaningQuick Fix
103Rollout switch lockoutInspect heat exchanger; reset switch
111No previous faultNormal after power cycle
114Blower on/off delayTiming fault; check blower
125Pressure switch faultCheck inducer, hose, drain trap
204Ignition lockoutCheck gas, igniter, flame sensor
223Limit switch openClean/replace filter; check blower
225Flame roll-out switch openSafety fault; inspect heat exchanger
231Gas valve faultGas valve or wiring issue
327Pressure switch stuck closedCheck pressure switch hose
332Inducer motor faultCheck inducer motor and wiring
411Flame sensed without callPossible gas valve leak
412Flame failureClean flame sensor; check gas
414Gas valve or roll-out faultCheck gas valve energization
432Communication faultCheck thermostat wiring
434Blower motor faultCheck motor and capacitor
540Board faultReplace IFC board
292Variable-speed blower faultCheck blower motor ECM

Technician Tips

Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

Most Common Codes

Code 204: Ignition Lockout

Four ignition attempts failed. On Lennox G61MPV and ML296V models, check the hot-surface igniter — Lennox uses a silicon nitride igniter rated at 40–90 ohms cold resistance. Also verify the gas supply is on and check the main gas valve operator coil for continuity (24V AC signal should reach the valve on a call for heat).

Code 223: High Limit Open

Limit switch tripped due to overheating. Replace the filter first — Lennox high-efficiency models use thick media filters that clog quickly. Also verify all supply and return registers are open. On variable-speed models (ML/EL/SL series), check that the ECM blower motor ramps up properly; a failing motor running at low speed causes repeated limit trips.

Code 225: Flame Roll-Out Switch Open

Hot gases backed out of the heat exchanger and melted a fuse link or tripped a manual-reset roll-out switch. This is a serious fault — do not simply reset without finding the cause. Possible causes: blocked flue pipe, cracked heat exchanger, excessive gas pressure, or blocked secondary heat exchanger on 90%+ models.

Code 412: Flame Failure

Burner lit briefly but flame wasn’t confirmed. Clean the flame sensor rod. On Lennox G61 series, the flame sensor is located in the rightmost burner position. Microamp signal should be above 1.5 µA; below 1.0 µA is unreliable.

Code 432: Communication Fault

On iComfort-equipped systems, the furnace and thermostat have lost the communication bus. Check the 2-wire thermostat cable and connections at both ends. A short in the communication wire is common if rodents have accessed the unit.

Code 292: Variable-Speed Blower Fault

The ECM blower motor on variable-speed Lennox furnaces has reported a fault. This can mean a failed motor, bad motor controller module, or communication error between the board and ECM. Start by checking all harness connectors to the motor.

When to Call a Pro

Codes 225 (roll-out) and 411 (flame without call) require professional inspection before the furnace is restarted. A cracked heat exchanger or leaking gas valve are not DIY repairs.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options