Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Troubleshoot Lennox error code 327 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Lennox error code 327 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Lennox fault code 327 is a limit fault — the high-temperature limit switch opened during a heating cycle. The limit switch is a thermal safety device in the heat exchanger plenum or supply air compartment. It opens when heat exchanger temperatures exceed the safe threshold (typically 140–200°F depending on switch rating), then resets automatically once temperatures drop. If the limit trips repeatedly, the board logs 327 and eventually locks out. Repeated limit trips mean either airflow across the heat exchanger is inadequate, or the heat exchanger itself is running too hot.
| Part | Notes |
|---|---|
| Air filter (1” or 4” media) | Replace on schedule; 1” filters need monthly checks in dusty environments |
| Blower motor capacitor | Test capacitance before condemning the motor |
| High-limit switch | Replace if it doesn’t reset after the system cools down |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the limit trips with a clean filter and a confirmed-running blower, the heat exchanger may be failing or the system is significantly oversized or underducted. A technician with a manometer can measure static pressure and identify whether the ductwork is the root cause.