Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Troubleshoot Lennox error code 225 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Lennox error code 225 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Lennox fault code 225 is a pressure switch fault — the board commanded the inducer on and waited for the pressure switch to confirm adequate draft, but the switch did not close within the allowed window. On high-efficiency (90%+) Lennox units, there are often two pressure switches (low-fire and high-fire), and code 225 typically applies to the primary draft proving switch. The furnace will not proceed to ignition and will retry a defined number of times before locking out. This fault is extremely common in winter when condensate freeze and flue blockages peak.
| Part | Notes |
|---|---|
| Pressure switch | Match exact setpoint — Lennox 90%+ units commonly use −0.6” or −1.0” W.C. |
| Pressure switch hose | Cheap; replace any hose that’s cracked, brittle, or clogged |
| Inducer housing gasket | Required if housing is leaking at the mounting interface |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the flue is clear, the pressure switch hose is dry, and a new pressure switch still doesn’t close with the inducer running, the inducer is likely not producing adequate draft — possibly due to a failed motor, cracked wheel, or significantly undersized flue run. This requires hands-on measurement and may require a venting redesign.