Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Troubleshoot Lennox 204 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Troubleshoot Lennox 204 on HVAC equipment with checks for power, airflow, sensors, ignition, safety circuits, and parts to price before service.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Lennox error code 204 means ignition failure — the furnace attempted to light the burners but failed to establish a flame within the allowed trial time. On iComfort systems this shows as “204” on the thermostat. On SureLight boards it appears as a flash sequence. The board allows 3 ignition attempts before locking out. Code 204 tells you the ignition sequence ran (draft proved, gas valve opened) but no stable flame was detected by the sensor. The igniter, gas supply, and flame sensor are the three components to check in that order.
| Part | Notes |
|---|---|
| Hot surface igniter | Lennox uses OEM part 62W21; verify for your model |
| Flame sensor | Universal fit for most Lennox units; $12–18 |
| Gas valve (24V) | Replace only after confirming voltage is present at valve terminals during trial |
Lennox furnace error codes are displayed as a series of LED flashes on the SureLight or integrated control board. A slow flash usually indicates normal operation, while rapid flashing points to a specific fault code. Code 1 = no previous code (normal standby). Code 2 = pressure switch failed open — check the vent, condensate drain, and inducer motor. Code 3 = pressure switch failed closed — replace the switch. Code 4 = high temperature limit — check airflow. Lennox systems with the SureLight igniter are particularly sensitive to gas pressure — verify 3.5” WC on natural gas before troubleshooting further. A 5-minute gas pressure check can save an hour of unnecessary component swapping.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If igniter and flame sensor check out and gas is confirmed at the valve, the issue is likely gas valve internal failure or a combustion problem that needs a combustion analyzer. These require a licensed tech.