Carrier Error Code 31 - Causes & Fix

3 min read
⚡ Quick Answer

Error code 31 means a pressure switch fault. The switch did not close or opened unexpectedly. Check vents and condensate drain first.

Difficulty Pro recommended
Est. time 1-3 hrs

Carrier Error Code 31 — What It Means

Error code 31 on a Carrier furnace indicates a pressure switch fault. The furnace’s low-pressure or high-pressure switch either did not close when the control board expected it to during startup, or it opened unexpectedly while the burners were running. The pressure switch is a safety device that monitors the draft created by the inducer motor. If the switch does not sense adequate draft (usually caused by blocked venting, a weak inducer, or a plugged condensate drain), it will not allow the burners to light or will shut them down.

This code protects against incomplete combustion and carbon monoxide risk. The most common real-world causes are blocked intake or exhaust vents, water or debris in the pressure switch tubing, a clogged condensate trap, or a failing inducer motor. Less often, the pressure switch itself has failed or there is a wiring problem. A cracked heat exchanger can also disrupt draft pressure, though this is much less common.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Confirm the error code by watching the furnace LED or display through a full startup attempt and verify that code 31 appears consistently.
  2. Inspect the pressure switch tubing for kinks, disconnections, cracks, or water inside the hose that runs from the inducer housing or draft assembly to the pressure switch.
  3. Check the exhaust vent and intake pipe outside the home for blockages such as ice, snow, debris, or animal nests, and verify that both terminations are clear and properly installed.
  4. Inspect and clean the condensate trap and drain line by removing the trap, flushing it with water, and confirming that condensate drains freely without backup into the inducer.
  5. Test the inducer motor by listening for smooth, strong operation when the furnace calls for heat, and feel for strong airflow at the draft outlet or intake if accessible.
  6. Test the pressure switch with a multimeter to confirm it opens and closes correctly, or use a manometer to measure draft pressure and compare to the switch’s rated actuation value if available in your model’s service manual.
  7. Check wiring and connections at the pressure switch, control board, and inducer, looking for loose spade terminals, corrosion, or damaged wires that could interrupt the signal.

Parts Often Needed

PartNotes
Pressure switchAmazon | Match the switch part number and pressure rating to your furnace model exactly.
Pressure switch tubingAmazon | Use clear or translucent tubing so you can inspect for water or blockage in the future.
Inducer motor assemblyAmazon | Choose OEM or direct-fit replacement for your Carrier model and serial number.

When to Call a Pro

Call a licensed HVAC technician if you have cleared all vents and drains, tested the pressure switch tubing, and the code persists. Diagnosing weak draft, measuring actual switch actuation pressure with a manometer, and testing for a cracked heat exchanger require professional tools and training. Also call a pro if you are uncomfortable working with gas appliances, electrical components, or disassembling the inducer and vent system. If the furnace is under warranty, professional documentation of the fault will be required for any covered parts.