Skip to content
Industrial Error Code Fixes
Go back

Carrier 13 Error Code — Limit Switch Lockout Fix

⚡ Quick Answer

Carrier error code 13 means limit-switch lockout from overheating. Check airflow, filter restriction, blower speed, limit switch, and heat exchanger risk.

⚡ AT A GLANCEScroll down for full repair guide
What it meansCarrier error code 13 means limit-switch lockout from overheating. Check airflow, filter restriction, blower speed, limit switch, and heat exchanger risk.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededCarrier high-limit switch
Repair intent

Need this fixed instead of diagnosed?

Carrier error code 13 means limit-switch lockout from overheating. Check airflow, filter restriction, blower speed, limit switch, and heat exchanger risk.

Parts to price first

Check the part before you book service.

Carrier high-limit switch

Part: HH12ZB195

Limit switch cited for code 13 thermal lockout checks.

Carrier ECM blower motor

Part: HC43AE116

Blower motor part listed for reduced airflow faults.

$200-$500 Check price

Blower motor run capacitor

Capacitor cited for humming or slow blower symptoms.

16x25x1 MERV 8 air filter

Filter size cited in the code 13 airflow parts table.

Error Code: Carrier 13

What it means: Code 1-3 is a limit switch lockout. The high-temperature limit switch inside the heat exchanger section tripped because the furnace sensed temperatures above the safe operating threshold (typically 200°F on the primary limit). This is a thermal safety device — when it trips, the gas valve closes but the blower continues running to cool the heat exchanger down. If the limit trips repeatedly, the board locks out with code 13.

The limit switch is doing exactly what it’s designed to do. The fault is almost never the switch itself — it’s whatever is causing the furnace to overheat.

Common Causes

Step-by-Step Fix {#step-by-step-fix}

  1. Check and replace the air filter immediately. Pull the filter, hold it to light — if you can’t see light through it, it’s too dirty. Replace it now with the correct size and MERV rating (MERV 8–11 is ideal for most residential systems; MERV 13+ can restrict airflow on older furnaces).

  2. Inspect and open all supply and return registers. Walk the home and confirm every register is open. Check for furniture blocking returns. The rule of thumb: never close more than 20% of supply registers on a forced-air system.

  3. Check blower wheel and motor operation. Remove the blower access panel (bottom of the furnace). Inspect the blower wheel for dust buildup — a caked blower wheel can reduce airflow by 30–40%. Clean with a brush and vacuum. Check that the blower runs at full speed during operation; a humming motor that doesn’t spin suggests a failed run capacitor.

  4. Test the run capacitor. With power OFF, discharge the capacitor (short its terminals through a 20K resistor), remove it, and test with a capacitor meter. The µF reading should be within 5–10% of the value printed on the capacitor label. Outside that range = replace.

  5. Inspect the flue pipe for obstructions. Trace the flue pipe from the furnace to the exterior and look for blockages, disconnected joints, or debris. A blocked flue prevents combustion gases from drafting and causes heat to back up into the heat exchanger.

  6. Manually reset the limit switch if needed. Many Carrier limit switches are auto-reset — they reset when the exchanger cools down. Some older or supplemental limit switches have a manual reset button (small red or white button on the switch body). Press it firmly. If the limit requires manual reset every heat cycle, the underlying cause has not been fixed.

  7. Check the heat exchanger for cracks. With the furnace off and cooled, insert a combustion analyzer probe into each heat exchanger cell and look for CO readings while the blower is running. Alternatively, watch for flame rollout or visible flame distortion through the sight glass during ignition. A cracked exchanger requires full replacement — do not continue operating.

  8. Verify return air temperature. Clip a thermometer to the return air plenum. Temperature should be 55–75°F during steady-state operation. Above 80°F return air (common in homes with returns too close to the furnace) indicates system-level airflow problems.

Parts That May Need Replacement {#parts-that-may-need-replacement}

PartTypical CostWhere to Buy
High-limit switch (Carrier #HH12ZB195 or equiv.)$15–$40Johnstone Supply
Blower motor run capacitor (match µF and voltage)$10–$30RepairClinic
ECM blower motor (Carrier OEM #HC43AE116)$200–$500RepairClinic
Air filter (16x25x1, MERV 8)$8–$25Home Depot

Technician Tips

Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.

Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.

Common replacement parts for Carrier systems:

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Professional

If you’ve replaced the filter, opened all registers, confirmed the blower runs at full speed, and the furnace still trips code 13 within one or two heat cycles — stop running the furnace and call a tech. At this point the most likely culprit is a cracked heat exchanger, which is a carbon monoxide hazard. Tell the tech: “Code 13 limit lockout, filter is new, blower runs fine, still tripping. I need a combustion analysis and heat exchanger inspection.”

Pro tip: A limit switch that trips in the first 5 minutes of a heat cycle (not the end) almost always points to a blower problem — the heat exchanger overheats before the blower gets it up to speed. A limit that trips after 20–30 minutes of continuous running usually points to airflow restriction (dirty filter, blocked registers). The timing tells you which direction to dig.

See Also


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options
Share this post on:

Previous Post
Trane Error Code 126 — Ignition Lockout Fix
Next Post
Carrier 21 Error Code — Gas Heating Lockout Fix