Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Carrier 58CVA furnace guide for flash codes, pressure switches, ignition lockouts, limit trips, flame sensing, inducer faults, and resets.
Carrier 58CVA furnace guide for flash codes, pressure switches, ignition lockouts, limit trips, flame sensing, inducer faults, and resets.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The Carrier 58CVA is a two-stage variable-speed gas furnace delivering 80% AFUE efficiency. It uses an ECM blower motor for variable airflow and a two-stage gas valve for improved comfort and dehumidification. The 58CVA communicates faults through a two-digit LED display on the control board — a more informative system than single-LED flash codes. Each code is a two-digit number that identifies both the fault category and specific condition.
| Code | Fault |
|---|---|
| 11 | No ignition — failed to light |
| 12 | Blower on after delay (not a fault — status) |
| 13 | Limit device lockout — exceeded 3 limit trips |
| 14 | Ignition lockout — exceeded 3 ignition failures |
| 21 | Gas heating lockout — control reset required |
| 22 | Abnormal flame sense current |
| 23 | Pressure switch stuck open |
| 24 | Secondary voltage fuse blown |
| 25 | Modulating gas valve fault |
| 31 | Pressure switch stuck closed |
| 32 | Pressure switch open during run |
| 33 | Limit circuit open |
| 34 | Igniter circuit open |
| 41 | Blower motor fault |
| 42 | Inducer motor fault |
| 43 | Condensate system fault (if equipped) |
| 44 | Flame sensed after gas valve closed |
| 45 | Control board fault |
| 46 | Incorrect line voltage (out of range) |
| 47 | Low-stage pressure switch stuck open |
| Part | Notes |
|---|---|
| Hot surface igniter | Silicon nitride; handle carefully, avoid touching ceramic |
| Flame sensor | Clean first; replace if cracked or reading <0.5 µA |
| ECM blower motor | Verify correct motor model; programmed to unit |
| Inducer motor | Match frame size and speed rating |
| High-limit switch | L170°F or L200°F depending on unit config |
| Pressure switch | Check tubing for blockage before replacing |
Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.
Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.
Common replacement parts for Carrier systems:
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
The 58CVA’s two-stage gas valve and ECM motor require familiarity with Carrier’s variable-speed control logic to diagnose correctly. If Code 45 (control board fault) appears, contact a Carrier authorized dealer — board replacement on a variable-speed furnace requires configuration matching the ECM motor and gas valve parameters.