York Rooftop Unit Error Codes - Predator and ZF RTU

⚡ Quick Answer

York RTU error-code guide for Predator, Affinity, and ZF rooftop units, including pressure lockouts, ignition faults, flame-sense errors, sensors, and blower faults.

⚡ AT A GLANCEScroll down for full repair guide
What it meansYork RTU error-code guide for Predator, Affinity, and ZF rooftop units, including pressure lockouts, ignition faults, flame-sense errors, sensors, and blower faults.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededYork RTU hot surface igniter
Repair intent

Need this fixed instead of diagnosed?

York RTU error-code guide for Predator, Affinity, and ZF rooftop units, including pressure lockouts, ignition faults, flame-sense errors, sensors, and blower faults.

Parts to price first

Check the part before you book service.

York RTU hot surface igniter

Match the RTU model, connector, mounting bracket, and igniter style before replacing ignition lockout faults.

York rooftop flame sensor

Clean and microamp-test the existing rod before replacing flame-sense faults.

York RTU pressure switch

Match high-side or low-side setting, tubing, and switch rating after proving the pressure condition.

York RTU run capacitor

Check microfarads and voltage rating before replacing blower or condenser fan capacitor faults.

York Rooftop Unit Error Codes: Complete Technician Guide

York commercial RTUs (Predator, Affinity, ZF, YCIV series) use LED flash codes and alphanumeric displays to communicate faults. York RTU equipment is also sold under the Luxaire and Coleman commercial brands with identical codes.

Reading York RTU Flash Codes

The IFC diagnostic LED flashes codes in groups:

York RTU Flash Code Table

Flash CodeFaultCommon Cause
2Low-pressure lockoutLow refrigerant charge
3High-pressure lockoutDirty condenser coil, fan failure
4Limit switch openAirflow restriction, dirty filter
5Rollout switch openCracked heat exchanger, blocked burner
6Ignition lockoutNo ignition after 3 attempts
7Flame signal lostDirty or failed flame sensor
8Blower motor faultMotor or capacitor failed
2-2Low-pressure switch stuck closedReplace pressure switch
3-3High-pressure switch stuck closedReplace pressure switch
4-1Primary limit faultOvertemperature — check airflow
4-2Secondary limit faultOvertemperature — check secondary limit
5-1Gas valve faultCheck valve and wiring
6-1Inducer faultCheck inducer motor and flue

York Predator/YSC Alphanumeric Codes

CodeDescriptionAction
E1Control board communication faultCheck wiring, replace board
E2Supply air sensor open/shortedCheck sensor resistance
E3Return air sensor faultCheck or replace sensor
E4Outdoor sensor faultCheck or replace outdoor sensor
E6High-pressure lockout — compressor 1Check condenser, coil, charge
E7High-pressure lockout — compressor 2Check condenser, coil, charge
E8Low-pressure lockoutCheck refrigerant charge
P1Low-ambient compressor lockoutAmbient below min — check lockout settings
P2Low-ambient heating lockoutAmbient below heating minimum

Most Common York RTU Faults

Flash 4 — Open Limit Switch

Dirty filter is the number-one cause. Check:

  1. Filter condition — replace if dirty
  2. All supply registers — confirm open
  3. Blower operation — check run capacitor
  4. Limit switch continuity — open at room temp = failed switch

Flash 6 — Ignition Lockout

E6/E7 — High Pressure Lockout

Flash 2 — Low-Pressure Lockout

Parts Commonly Replaced

PartNotes
Hot surface igniterSilicon carbide — handle with gloves
Flame sensorMeasure µA output; replace below 1.5 µA
Limit switchMatch temperature rating
Run capacitorCheck µF before condemning motor
Pressure switchHigh or low side — match setting
IFC boardYork part number varies by model year

Need Replacement Parts?

Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

Note: York, Luxaire, and Coleman commercial RTUs share the same IFC control boards and fault codes. Parts are fully interchangeable across brands.

Quick FAQ

What do York rooftop unit flash codes usually point to?

York RTU flash codes usually point to pressure lockouts, limit faults, rollout faults, ignition lockout, flame-sense loss, blower faults, or high and low pressure switch problems.

What should I check first on a York RTU ignition lockout?

Check the hot surface igniter, flame sensor, gas pressure, rollout switches, venting, and ignition wiring before replacing the IFC board.

Are York, Luxaire, and Coleman RTU parts interchangeable?

Many York, Luxaire, and Coleman commercial RTUs share Johnson Controls platforms, but parts still need to match the full model, serial, voltage, and control-board revision.


Need a professional? Compare HVAC repair options before replacing parts.