Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
York 4 flashes means the high limit switch opened due to overheating. This guide covers every cause and fix for the York furnace 4-flash open limit fault.
York 4 flashes means the high limit switch opened due to overheating. This guide covers every cause and fix for the York furnace 4-flash open limit fault.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
What it means: Four flashes on a York furnace diagnostic LED indicates an open high limit device. York furnaces (including Coleman and Luxaire, which share the same boards) use a normally-closed high limit switch mounted in the heat exchanger plenum. This switch opens when supply air temperature exceeds its rated setpoint — typically 160–180°F. When the limit opens, the gas valve closes immediately but the blower continues to run until the plenum cools and the limit resets. If the underlying cause of overheating is not addressed, the limit will trip repeatedly, and the board may lock out.
Fix airflow first. Replace the filter. Open all registers. If the capacitor reads below 10% of rated MFD, replace it before replacing the motor. Blower capacitors on York/Coleman furnaces are typically 5–7.5 MFD and available from any HVAC parts supplier.
If the limit switch has failed, replace it. York furnaces use multiple limit switch ratings across their model lineup — match the temperature rating and mounting style exactly. Order using the furnace model number.
| Part | Where to Buy |
|---|---|
| High limit switch | RepairClinic, SupplyHouse |
| Blower motor run capacitor | Grainger |
| PSC blower motor | RepairClinic, Grainger |
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the 4-flash fault persists after filter replacement and airflow correction, have a licensed HVAC technician inspect the heat exchanger for cracks before continued operation.