Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
York Affinity packaged unit error codes and fault diagnostics. Flash codes, communicating system faults, and technician-level troubleshooting.
York Affinity packaged unit error codes and fault diagnostics. Flash codes, communicating system faults, and technician-level troubleshooting.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
York Affinity packaged units use an LED diagnostic system on the Integrated Furnace Control (IFC) board. Flash codes identify faults. Units with the York Affinity Communicating System display codes on a thermostat. Fault history is stored in the control board.
| Code | Fault Description | Common Cause | Action |
|---|---|---|---|
| 2 | Pressure switch stuck closed | Shorted switch or wiring | Check switch and wiring |
| 3 | Pressure switch open | Blocked inducer port, failed switch | Measure inducer flue pressure |
| 4 | Open high-limit | Restricted airflow | Replace filter, check duct |
| 5 | Flame sensed with no call | Leaking gas valve | Replace gas valve |
| 6 | Ignition failure | Gas, spark, or sensor issue | Check gas pressure and igniter |
| 7 | Limit switch lockout | Repeated overtemperature | Resolve airflow restriction |
| 8 | Low-pressure switch | Low refrigerant, iced coil | Check charge and defrost |
| 9 | High-pressure switch | Dirty coil, failed condenser fan | Clean coil, check fans |
| 10 | Defrost fault | Defrost board or sensor | Check sensor clip position |
| 11 | Blower fault | Failed motor or relay | Check motor amps and relays |
York Affinity units are available in gas heat versions where limit trips are common with dirty filters. The limit opens at 150-200 degrees F depending on model. Replace the filter, verify all supply registers are open, and check blower RPM.
Check in sequence: induced draft motor running, pressure switch proven, gas valve opens (listen/check inlet pressure), spark at igniter (1/8” gap), and flame sensor signal (microA). Clean flame sensor first.
R-410A high-side must stay below 590 psi. Wash condenser coil, check condenser fan rotation - it must pull air through the coil. Verify unit is not operating in excessive ambient temperature.
| Part | Notes |
|---|---|
| IFC board | Match to unit model |
| Flame sensor | Measure microA first |
| Pressure switch | Match pressure setpoint |
| Limit switch | Match temperature rating |
| Run capacitor | Test microF with meter |
| Blower motor | Check for ECM vs. PSC type |
Heat-pump, rooftop, and air-conditioner faults usually come from airflow, condensate drainage, outdoor coil condition, defrost sensors, pressure switches, capacitors/contactors, or low-voltage communication. Check filters, coils, drains, disconnect power, and thermostat wiring before assuming the compressor or board has failed.
DIY vs Pro: Filter, coil, drain, and visual wiring checks are reasonable owner tasks. Refrigerant diagnostics, capacitor testing, contactor replacement, and compressor or control-board work should be done by an HVAC technician.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: York Affinity units with the communicating system log fault timestamps. Always retrieve fault history via thermostat diagnostics menu before clearing - provides valuable intermittent fault pattern data.