Quincy QGS rotary screw compressors use the Intellizone II controller. Fault codes and messages display on the Intellizone panel LCD. The controller stores fault history with run hours and timestamps.
| Code/Message | Fault Description | Common Cause | Action |
|---|---|---|---|
| HIGH TEMP | High discharge temperature | Dirty cooler, low oil, high ambient | Clean cooler, check oil |
| HIGH TEMP WARN | Temperature approaching limit | Pre-shutdown warning | Clean cooler immediately |
| MOTOR OVERLOAD | Motor thermal trip | Excessive current or load | Check motor amps and load |
| HIGH PRESSURE | System pressure too high | Excessive demand | Check pressure setting |
| LOW OIL PRESSURE | Oil pressure insufficient | Low oil or failed pump | Check oil level and pump |
| PHASE LOSS | Missing supply phase | Fuse or supply fault | Check input power |
| INLET RESTRICTION | Dirty inlet filter | Restricted air intake | Replace inlet filter |
| EMERGENCY STOP | E-stop active | E-stop circuit open | Check E-stop wiring |
| CHECK SEPARATOR | Separator element pressure drop high | Dirty separator | Replace separator element |
| SERVICE DUE | Maintenance interval reached | Hours elapsed | Perform scheduled PM |
| SENSOR FAULT | Failed temperature sensor | Open or shorted sensor | Replace thermistor |
| AUTO DRAIN FAULT | Condensate drain valve fault | Solenoid valve failure | Check drain valve |
Quincy QGS compressors have a high-temperature shutdown at typically 228 degrees F (109 degrees C). The most common cause is a dirty oil cooler or air aftercooler. Blow fins clean with low-pressure air. On larger QGS models, the cooler can be removed for power washing with degreaser.
Check that the motor overload relay is set correctly: current setting should be 100-105% of motor nameplate FLA. Verify three-phase voltage balance - more than 3% imbalance causes disproportionate current in one phase.
When separator differential pressure exceeds design maximum (typically 10 PSI), this alarm triggers. The separator element is a wear item - replace at the scheduled interval (typically 4,000 hours). A clogged separator element increases discharge temperature and reduces compressor efficiency.
Quincy QGS has an electronic auto-drain to remove condensate from the separator tank. If the solenoid valve fails (stuck closed = water in oil; stuck open = air loss), this fault triggers. Check solenoid valve coil resistance and verify 24 VAC at coil during drain cycle.
| Part | Notes |
|---|---|
| Inlet air filter | Model-specific |
| Oil/separator element | Replace per service schedule |
| Quincy QGS oil | Synthetic - match model specification |
| Auto-drain solenoid | Check coil resistance |
| Temperature thermistor | NTC type - check resistance vs. temp chart |
| Motor overload relay | Match FLA setting |
Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: Quincy QGS Intellizone II logs the last 10 faults with run hours. Access via MENU -> HISTORY -> FAULT LOG on the panel. If HIGH TEMP faults are increasing in frequency, track the interval between faults - progressive reduction in time between faults indicates a degrading cooler before total failure.