Quincy Compressor Fault Codes

⚡ Quick Answer

Quincy compressor fault guide for QGS/QGV alarms, high discharge temp, transducers, separator service, oil filters, fans, and motor trips.

⚡ AT A GLANCEScroll down for full repair guide
What it meansQuincy compressor faults on QGS, QGV, and related rotary-screw packages point to high temperature, motor overload, pressure-sensor trouble, phase faults, VSD trips, low oil, service alarms, or E-stop circuits.
Most likely causeCommon causes include dirty coolers, low or wrong oil, blocked airflow, failed fan motors, voltage imbalance, weak contactors, drifting pressure transducers, loaded starts, separator restriction, or overdue PM.
First checkRecord the controller alarm, compare pressure readings to a mechanical gauge, check oil level and cooler cleanliness, verify fan and contactor operation, and measure incoming phase voltage before replacing sensors or drive parts.
⏱Repair timePlan 20-45 minutes for oil, cooler, fan, pressure, and phase checks; separator service, transducer replacement, or VSD diagnosis can take 1-2 hours.
🔧Part neededPressure transducer, air-oil separator element, oil filter, compressor fan motor contactor.
Repair intent

Need this fixed instead of diagnosed?

Quincy compressor fault guide for QGS/QGV alarms, high discharge temp, transducers, separator service, oil filters, fans, and motor trips.

Parts to price first

Check the part before you book service.

Quincy compressor pressure transducer

Price after comparing controller pressure to a calibrated mechanical gauge.

Quincy air oil separator element

Common service item for oil carryover, pressure drop, and overload issues.

Quincy compressor oil filter

Replace during PM or low-oil troubleshooting with the correct compressor oil.

Compressor fan motor contactor

Inspect on temperature faults after confirming the fan motor and supply voltage.

Quincy Compressor Fault Codes — Quick Reference

Quincy rotary screw compressors use controller alarms for high temperature, motor overload, pressure switch problems, and service intervals. QGS and QGV units also carry VSD-related alarms on variable-speed models.

AlarmMeaningQuick Fix
High TempDischarge or oil temp too highClean coolers; check oil
Motor OverloadMain motor current highCheck load and voltage
Pressure Sensor FaultBad transducer signalInspect sensor and wiring
Phase FaultInput phase loss / reversalCheck incoming power
VSD FaultDrive-level tripRead drive history
Service AlarmPM duePerform scheduled maintenance
E-StopEmergency stop activeReset circuit
Low Oil ShutdownLubrication issueCheck oil and filters

Most Common Faults

High Temp

High-temperature alarms on Quincy screws are almost always maintenance-related. Dirty coolers, wrong oil, low oil level, or failed fan motors are the first checks. Cleanliness matters more than people realize on screw compressors.

Phase Fault

If a Quincy compressor shows a phase fault after electrical work, verify phase sequence and voltage balance at the disconnect. Loose lugs and weak contactors create intermittent phase-loss alarms under load.

Pressure Sensor Fault

A dead or drifting pressure transducer makes the controller do strange things, including bad load/unload behavior and nuisance shutdowns. Compare the controller pressure reading to a calibrated mechanical gauge before replacing valves.

Parts Often Needed

PartNotes
Pressure transducerFrequent electronic failure
Air/oil separatorMajor service item
Oil filterReplace during PM
Fan motor / contactorCheck on temperature faults

Need Replacement Parts?

Before ordering, match the commercial equipment part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

If the compressor is tripping on high temp after cooler cleaning and PM service, the oil thermostatic valve or airend may be wearing out. That is specialist work.

Quick FAQ

What causes a Quincy compressor high-temperature alarm?

High-temperature alarms are usually maintenance-related. Check dirty coolers, low or wrong oil, blocked airflow, and failed fan motors before suspecting the airend.

How do you diagnose a Quincy pressure sensor fault?

Compare the controller pressure reading with a calibrated mechanical gauge. A drifting or dead transducer can cause bad load/unload behavior and nuisance shutdowns.

What does a Quincy compressor phase fault mean?

A phase fault points to input phase loss, reversed phase sequence, voltage imbalance, loose lugs, or weak contactors, especially after recent electrical work.