Your LG window air conditioner flashes CH02 on the display. The unit stops cooling. This is an indoor evaporator thermistor fault. Here is what it means and how to fix it yourself.
| Code | Meaning | Severity | DIY Fixable? |
|---|---|---|---|
| CH02 | Indoor evaporator coil temperature sensor fault | Moderate | Yes — sensor replacement |
The CH02 error code tells you the evaporator coil temperature sensor (also called the indoor thermistor) is not sending a signal the control board can read. This sensor sits embedded in the evaporator coil fins. It tells the board when the coil is cold enough to start running the fan and when it is getting too cold and might freeze.
When this sensor fails, the control board cannot know the coil temperature. It shuts down the compressor and fan for safety. That is the CH02 error.
Unplug the air conditioner from the wall outlet. Wait 10 minutes. Plug it back in. This clears transient errors that sometimes happen during brownouts or power surges.
If the CH02 code goes away and the AC runs normally, the sensor and board are fine. The issue was voltage fluctuation. If the code comes right back, move to Step 2.
Unplug the AC. Remove the front grille and filter. Take off the metal control panel cover. Locate the evaporator coil — the cold finned section at the front of the unit. Follow the two small wires from the coil back to the control board connector.
Look for:
If you find a loose wire, reconnect it firmly. If you see corrosion, cut back to clean wire and use a butt splice connector.
Disconnect the thermistor from the control board. Set your multimeter to resistance (ohms, the Ω symbol). Place one probe on each thermistor wire.
At room temperature (around 77F / 25C), a good thermistor reads approximately 10,000 ohms (10kΩ). The exact reading varies slightly by temperature. Here are typical values:
If your reading is open (OL on the meter) or shorted (0 ohms), the thermistor is bad. If the reading is far outside the expected range (below 2kΩ or above 100kΩ at room temp), the thermistor has drifted out of spec.
If the thermistor failed the resistance test, replace it.
If the new thermistor did not fix the error, the control board itself may be at fault. This is less common but happens after a power surge or if the original thermistor shorted and damaged the board.
Before ordering a board:
If the board looks damaged, order an LG control board specific to your model.
Call a technician if: