Temperature sensor
Common error-code part. Confirm resistance and connector style.
Fix LG window AC CH01 error code indicating a room temperature thermistor fault with these DIY repair steps.
Fix LG window AC CH01 error code indicating a room temperature thermistor fault with these DIY repair steps.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
When your LG window air conditioner flashes CH01 on the display, the unit is telling you the room temperature sensor (a thermistor) has failed. AC units need a working temperature sensor to know when to turn the compressor on and off. Without it, the unit either runs nonstop, won’t run at all, or throws the CH01 code.
The good news: this is a cheap and easy fix. A thermistor costs around $10–$20 and takes about 20 minutes to swap. Here’s exactly how to do it.
| Code | Meaning | Severity | DIY Fix? |
|---|---|---|---|
| CH01 | Room temperature thermistor open or shorted | Low to Moderate | Yes — easy replace |
Before opening anything, a full power cycle can clear a false CH01 code. This is worth trying first.
If CH01 comes back, the sensor is genuinely bad. Move to Fix 2.
The room temperature sensor is a small thermistor bead located behind the front grille of the unit. Before testing, check the wiring for obvious damage.
If you find a damaged wire, you can splice it with wire connectors or replace the entire sensor.
Now you need to confirm the sensor itself is bad. Grab a multimeter.
What you should see at room temperature (around 70–77°F):
The relationship is inverse — as temperature goes up, resistance goes down. If the reading is OL (open loop), 0Ω, or any value that doesn’t change when you warm the bead with your fingers (temperature coefficient test), the thermistor is bad.
Note: Some LG window ACs use a different thermistor value (5kΩ or 15kΩ at room temp). If you get a stable reading but are unsure, check your model number against the service manual. A value that doesn’t respond to temperature changes is the real giveaway.
If the thermistor tested bad, replacement is straightforward.
Set the AC to Cool and let it run for 20 minutes. If the compressor kicks on and the room cools down, you fixed it.
If CH01 persists after replacing the thermistor, the control board itself may have a bad sensor circuit. This is less common but possible.
Board replacements on window ACs are usually only worth it on larger units (10,000+ BTU). On a small unit, buying a new AC may be cheaper.
The CH01 code is one of the simpler AC error codes because the room thermistor is a standalone component — easy to access, easy to test, and cheap to replace. Unlike codes related to the compressor or refrigerant charge, there’s no special equipment needed. If you own a multimeter and can turn a screwdriver, you can handle this one.