Temperature sensor
Common error-code part. Confirm resistance and connector style.
What Carrier heat pump E5 means, why defrost fails, and how to fix E5 error codes on Carrier heat pump systems.
What Carrier heat pump E5 means, why defrost fails, and how to fix E5 error codes on Carrier heat pump systems.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
Carrier heat pump error code E5 indicates a defrost fault — the heat pump’s defrost cycle either failed to initiate, failed to complete, or the outdoor coil thermistor detected an abnormal temperature condition. E5 appears on Carrier mini-split and ductless heat pump displays (models like the Carrier Performance 40MAQB, 40GRB, and Infinity heat pump systems). On some split-system heat pumps, E5 may also appear on the thermostat or the air handler display.
| Part | Notes |
|---|---|
| Outdoor coil thermistor | Carrier 338818-702 or model-specific |
| Reversing valve solenoid coil | 24V AC solenoid coil |
| Reversing valve (if stuck) | Mechanical replacement — requires brazing |
Carrier uses different diagnostic systems across furnaces, heat pumps, chillers, mini-splits, VRF equipment, rooftop units, and communicating controls. Confirm the full model number and whether the fault came from the indoor board, outdoor board, thermostat, or equipment controller before matching it to a repair path.
Start with power, wiring, airflow or water-flow, sensor, condensate, and safety-circuit checks before ordering control boards. If the same code returns after one reset and the basic cause is not obvious, test the named circuit instead of repeatedly cycling the equipment.
Parts note: For Carrier heat-pump defrost faults, prioritize the outdoor coil sensor, ambient thermistor, defrost board, reversing-valve coil, and fan components before considering larger replacements.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Low refrigerant charge and reversing valve replacement require an EPA 608-certified HVAC technician. Don’t ignore E5 — running a heat pump with a failed defrost system causes ice to accumulate and can damage the outdoor fan blade and coil.