Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
York YG2C flash codes identify ignition, pressure switch, flame, rollout, limit, and inducer faults on YG2C gas furnaces.
York YG2C flash codes identify ignition, pressure switch, flame, rollout, limit, and inducer faults on YG2C gas furnaces.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The York YG2C is a two-stage, variable-speed gas furnace in the Affinity series. It uses an ECM blower and communicates fault conditions through a diagnostic LED on the control board. The YG2C supports York’s Affinity communicating thermostat, which can display readable fault descriptions. For non-communicating systems, read the LED flash code directly.
| Flash Code | Meaning |
|---|---|
| 1 flash | Normal — call satisfied |
| 2 flashes | Lockout — ignition failure |
| 3 flashes | Pressure switch stuck open |
| 4 flashes | High-limit switch open |
| 5 flashes | Flame detected without call |
| 6 flashes | 115V power fault or reversed polarity |
| 7 flashes | Gas valve circuit fault |
| 8 flashes | Weak flame signal |
| 9 flashes | Rollout switch open |
| 10 flashes | Inducer or pressure switch fault (low fire) |
| 11 flashes | Blower motor fault |
| 12 flashes | Limit device lockout (repeated trips) |
| 13 flashes | Control board fault |
| Part | Notes |
|---|---|
| Hot surface ignitor | York/Nordyne-specific; confirm model compatibility |
| ECM blower module | Rear of motor; test before replacing full motor |
| Pressure switch | Confirm low-fire and high-fire ratings separately |
| Rollout switch | Manual reset; investigate root cause |
| High-limit switch | Auto-reset; check continuity |
| Control board | For Code 13 or unexplained faults |
Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.
DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
The YG2C’s two-stage gas valve and variable-speed ECM blower are complex enough that board-level diagnosis benefits from York’s proprietary tools. If you’re chasing intermittent faults across multiple codes, an Affinity-compatible communicating thermostat will show detailed fault history that flash codes don’t capture.