Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
York TG9 furnace fault codes for pressure switch, limit, ignition, rollout, blower, control-board, and communication faults.
York TG9 furnace fault codes for pressure switch, limit, ignition, rollout, blower, control-board, and communication faults.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
The York TG9 is a 96% AFUE two-stage variable-speed gas furnace. It is part of York’s Affinity series and uses a communicating control board when connected to a York proprietary thermostat, or a standalone LED diagnostic when used with a conventional thermostat. The TG9 uses an ECM blower motor for variable airflow and a two-stage gas valve for comfort-based modulation. It vents via PVC condensing flue and produces condensate requiring a drain trap.
| Flash Sequence | Fault |
|---|---|
| 1 flash | Normal — waiting for call |
| 2 flashes | Pressure switch stuck open |
| 3 flashes | Pressure switch stuck closed |
| 4 flashes | High-limit switch open |
| 5 flashes | Ignition lockout — 3 failed attempts |
| 6 flashes | Rollout switch open |
| 7 flashes | Flame sensed without gas valve call |
| 8 flashes | Inducer motor speed fault |
| 9 flashes | Blower motor fault |
| 10 flashes | Control board fault |
| 11 flashes | Communication fault (if connected to York thermostat) |
| Rapid | Low voltage — below 18VAC |
| Part | Notes |
|---|---|
| Hot surface igniter | Silicon nitride; specific to TG9 model |
| Flame sensor | Rod-type; clean before replacing |
| Condensate trap | PVC trap assembly; critical to pressure switch operation |
| ECM blower motor module | Module only — verify motor spins freely before replacing |
| Inducer motor assembly | ECM type; includes tach feedback |
| Pressure switch | Check tubing and condensate trap first |
Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.
DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
The York TG9 ECM motor and variable-speed control logic require familiarity with York’s communicating control system. If the TG9 is installed with a York proprietary thermostat and showing thermostat-level fault codes, a York dealer with system diagnostic tools is needed for full root-cause analysis. Rollout switch trips (Code 6) must be investigated for heat exchanger integrity before returning to service.