York TG9 Furnace Error Codes - Fault Code Guide

⚡ Quick Answer

York TG9 furnace fault codes for pressure switch, limit, ignition, rollout, blower, control-board, and communication faults.

⚡ AT A GLANCEScroll down for full repair guide
What it meansYork TG9 furnace fault codes for pressure switch, limit, ignition, rollout, blower, control-board, and communication faults.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

York TG9 furnace fault codes for pressure switch, limit, ignition, rollout, blower, control-board, and communication faults.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

York TG9 Furnace Error Codes — What They Mean

The York TG9 is a 96% AFUE two-stage variable-speed gas furnace. It is part of York’s Affinity series and uses a communicating control board when connected to a York proprietary thermostat, or a standalone LED diagnostic when used with a conventional thermostat. The TG9 uses an ECM blower motor for variable airflow and a two-stage gas valve for comfort-based modulation. It vents via PVC condensing flue and produces condensate requiring a drain trap.

Jump to Fix

York TG9 LED Flash Code Reference

Flash SequenceFault
1 flashNormal — waiting for call
2 flashesPressure switch stuck open
3 flashesPressure switch stuck closed
4 flashesHigh-limit switch open
5 flashesIgnition lockout — 3 failed attempts
6 flashesRollout switch open
7 flashesFlame sensed without gas valve call
8 flashesInducer motor speed fault
9 flashesBlower motor fault
10 flashesControl board fault
11 flashesCommunication fault (if connected to York thermostat)
RapidLow voltage — below 18VAC

Common Causes by Code

Step-by-Step Fix

  1. Read the LED — The York TG9 LED is inside the control compartment, visible through the observation window in the lower panel. Count the flash sequence (flashes, then pause, then repeat).
  2. For 2 flashes (pressure switch) — Locate the condensate trap (under the secondary heat exchanger or inside the furnace cabinet). Remove the trap and flush it with water. Reconnect and restart. If the fault clears, the condensate drain was blocked.
  3. For 5 flashes (ignition lockout) — Reset by pressing the board’s reset button or cycling power at the furnace switch. Watch the ignition sequence on restart: inducer → pressure switch closes → igniter heats → gas valve opens. Each step should happen in sequence within 30–60 seconds.
  4. For 8 flashes (inducer speed) — Check the inducer motor tach wire. It is a small-gauge wire (often white or yellow) connected to a 3-pin connector on the inducer motor. Verify the connector is fully seated.
  5. For 9 flashes (blower) — Verify the ECM motor is getting 120VAC at the motor power connector. Check the communication cable (5-pin) between the motor module and the board. If the motor runs but slowly, the motor module may need replacement.

Parts Often Needed

PartNotes
Hot surface igniterSilicon nitride; specific to TG9 model
Flame sensorRod-type; clean before replacing
Condensate trapPVC trap assembly; critical to pressure switch operation
ECM blower motor moduleModule only — verify motor spins freely before replacing
Inducer motor assemblyECM type; includes tach feedback
Pressure switchCheck tubing and condensate trap first

Technician Tips

Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.

DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.

Need Replacement Parts?

Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

The York TG9 ECM motor and variable-speed control logic require familiarity with York’s communicating control system. If the TG9 is installed with a York proprietary thermostat and showing thermostat-level fault codes, a York dealer with system diagnostic tools is needed for full root-cause analysis. Rollout switch trips (Code 6) must be investigated for heat exchanger integrity before returning to service.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options