Igniter
Price the ignition part only after confirming the model number and connector.
Diagnose York Furnace E4 Error Code - Ignition Failure: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Price the ignition part only after confirming the model number and connector.
Common lockout part on gas heat and burner systems.
Relevant for pilot-safety and older gas appliance faults.
Restricted airflow trips high-limit, low-airflow, and frozen-coil faults. Filter King cuts custom sizes if the standard size is out of stock.
Stock a year of filters so the airflow fault does not come back after the fix.
Standard and odd sizes in MERV 8, 11, and 13. Match the MERV your blower is rated for; a filter that is too restrictive trips the same airflow faults as a dirty one.
Limit switches, sequencers, blower motors, and control boards for Nordyne, Intertherm, Miller, and Coleman furnaces.
Wholesale-priced OEM-equivalent parts and full systems shipped direct. Compare before paying contractor markup on a replacement.
Diagnose York Furnace E4 Error Code - Ignition Failure: likely causes to check, measurements to verify, and repair decisions before parts replacement.
On York furnaces with LED display panels (YP9C, TM9V, and related models), E4 indicates an ignition failure — the control board attempted to light the burners, but no flame was detected within the trial-for-ignition period. After typically three failed ignition attempts, the board locks out and displays E4. This is a safety lock that prevents unburned gas from accumulating. The furnace will remain locked out until the fault is cleared.
| Part | Notes |
|---|---|
| Hot surface ignitor | Match exact part — York uses both 120V silicon carbide and 80V silicon nitride types |
| Flame sensor | Universal sensors work but OEM preferred for reliability |
| Gas valve | Replace only after confirming 24VAC at valve terminals with no gas flow |
| Control board | Last resort — if ignitor, sensor, and gas valve all check out |
Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.
DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Gas valve replacement requires leak-testing all connections with a manometer or soap solution. If you’re not comfortable working with gas lines or you have propane (higher pressure, different hazard profile), call a licensed HVAC technician.