York Affinity hot surface igniter
Part: S1-02528326000
Part listed for Code 4-1 ignition failure.
York Affinity furnace guide for ignition, inducer, pressure-switch, limit, rollout, flame-sense, and control-board fault codes.
York Affinity furnace guide for ignition, inducer, pressure-switch, limit, rollout, flame-sense, and control-board fault codes.
Parts to price first
Part: S1-02528326000
Part listed for Code 4-1 ignition failure.
Part: S1-02435625000
Part listed for Code 3-3 inducer faults.
Part: S1-02528333000
Part listed for Code 2-1 after hoses and drains check out.
Part: S1-02535710000
Part listed for Code 3-1 when airflow issues are ruled out.
Part: S1-33102956000
Board listed for Code 7-1; verify model and existing board number.
York Affinity is York’s premium residential product line, covering high-efficiency furnaces (96%+ AFUE) and heat pumps. The Affinity series includes models like the TG9S, YP9C, YZF, and YZV. Like most modern HVAC equipment, these units use a diagnostic LED to report fault codes when something goes wrong. This guide covers the full flash code library for York Affinity furnaces and the most common heat pump codes.
For York Affinity furnaces, there’s a small status LED visible through the sight glass on the furnace door panel. It blinks a two-digit code: count the short blinks (first digit), wait for the pause, then count the longer blinks (second digit). The pattern repeats continuously until the fault clears.
On communicating Affinity systems (matched with a York Latitude or Affinity thermostat), the thermostat screen shows the fault code directly — no counting required.
| Code | Fault Description | Urgency |
|---|---|---|
| 1-1 | Normal — no call for heat | None |
| 1-2 | Normal — heating | None |
| 2-1 | Pressure switch stuck open | High |
| 2-2 | Pressure switch stuck closed | Medium |
| 2-3 | Secondary pressure switch stuck open | High |
| 2-4 | Secondary pressure switch stuck closed | Medium |
| 3-1 | Primary limit switch open | High |
| 3-2 | Secondary limit / rollout switch open | Critical |
| 3-3 | Draft inducer motor fault | High |
| 3-4 | Blower motor fault | High |
| 4-1 | Ignition failure — lockout | High |
| 4-2 | Flame sensor fault | Medium |
| 4-3 | Flame detected with valve closed | Critical |
| 5-1 | Gas valve 1 circuit fault | High |
| 5-2 | Gas valve 2 circuit fault | High |
| 6-1 | Low flame signal | Medium |
| 6-2 | Communication error | Medium |
| 7-1 | Control board fault | Critical |
The pressure switch monitors draft (negative pressure created by the inducer motor). When it reads open, the furnace won’t fire because it can’t confirm safe venting conditions.
Walk through in order:
Overheating. The heat exchanger surface temperature exceeded the limit (typically 140°F–170°F on Affinity furnaces). Check the filter first. A clogged filter is the cause in more than half of 3-1 codes.
After filter replacement: check that every supply register in the house is open, verify the return air system isn’t undersized or blocked, and confirm the blower wheel is clean.
Flames escaped the combustion chamber. This is a safety shutdown that demands investigation before restarting. Press the red manual reset button on the rollout switch (located near the burners). If it trips again within a heating cycle, do not restart — a cracked heat exchanger or blocked flue is likely.
The furnace tried to ignite three times and gave up. Possible causes:
Test the igniter by measuring its resistance (should read 40–90 ohms on most York Affinity igniters). Infinite resistance = cracked igniter.
The flame sensor is detecting a flame when the gas valve should be closed. This is either a shorted flame sensor, a faulty control board, or (rarely) a gas valve leaking through. Turn off gas and call a technician.
The control board has detected an internal fault. Try cycling power at the disconnect for 30 seconds. If the code returns immediately, the board needs replacement. York Affinity boards are model-specific — always verify the part number on the existing board before ordering.
| Part | Why You Need It | Approx. Cost |
|---|---|---|
| Hot surface igniter (York S1-02528326000) | Fixes Code 4-1 ignition failure | |
| Flame sensor (universal 1/4” rod) | Fixes Code 4-2 flame sense fault | |
| Draft inducer motor (York S1-02435625000) | Fixes Code 3-3 inducer fault | |
| Pressure switch (York S1-02528333000) | Fixes Code 2-1 when hose is clear | |
| High limit switch (York S1-02535710000) | Fixes Code 3-1 when limit is failed | |
| Control board (York S1-33102956000) | Fixes Code 7-1 board fault |
Need replacement parts? Search for parts and tools on Amazon.
Q: My York Affinity TG9S is showing a 2-1 code every winter but fine the rest of the year. Why is it seasonal?
A: This is classic condensate trap blockage. 90%+ furnaces produce water as a byproduct of combustion. In winter, with the furnace running constantly, the condensate drain path can partially freeze or develop a biofilm blockage. The water backs up into the inducer housing, blocking the pressure tap port, and the switch trips. Flush the condensate trap and drain line each fall before heating season.
Q: Can I use an aftermarket control board on a York Affinity furnace?
A: Technically yes, but be careful. York Affinity boards are not universal — they match specific motor configurations and gas valve types. Using a generic board often requires re-wiring and may disable safety features. Source an OEM replacement board using the part number from your existing board. Used boards from eBay can work but come with obvious risks.
Q: The York Affinity furnace blinks 3-4 (blower motor fault). The blower runs fine in cooling mode. What’s different in heating?
A: In heating mode, the blower typically runs at a different speed tap than in cooling. A failed speed tap on an ECM (variable speed) blower motor can cause the blower to work on one speed setting but fail on another. Have a tech test the motor’s full speed range. On older PSC motors, a failed capacitor (which is speed-specific) can cause the same issue.
Q: York Affinity showing code 6-1 (low flame signal) and the flame sensor is brand new. What else could cause this?
A: Ground path. The flame sensor works by passing a small current through the flame — the current only completes if the burner has a solid chassis ground. Check that the burner itself has good metal-to-metal contact with the furnace casing. A corroded or painted-over ground connection will cause low flame signal even with a new sensor. Also check gas pressure — low supply pressure produces a smaller flame that’s harder to sense.
Q: How long should a York Affinity furnace last?
A: With annual maintenance (filter changes, cleaning, safety checks), a York Affinity can last 20–25 years. The heat exchanger typically outlasts other components. The most common age-related failures are the igniter (every 5–10 years), the inducer motor (10–15 years), and the control board (10–15 years). None of these are reasons to replace the whole system.
Record the full model number, exact code, and operating mode before replacing parts. Similar code labels can point to different sensors, pumps, boards, or wiring circuits across product families.
Reset once after correcting an obvious cause. If the code returns immediately, leave the equipment off and test the named circuit instead of repeatedly cycling power.