Skip to content
Industrial Error Code Fixes
Go back

Yaskawa GA800 E04 Fault Code - Causes & Fix

3 min read
⚡ Quick Answer

E04 on a Yaskawa GA800 is not a standard fault code in manufacturer manuals. Learn how to verify the display and troubleshoot.

Difficulty Advanced
Est. time 1-3 hrs
Tools Multimeter , service manual, ESD strap

Yaskawa GA800 E04 Fault Code — What It Means

E04 does not appear in the verified Yaskawa GA800 fault and alarm tables found in the manufacturer’s documentation. Yaskawa distinguishes between faults, alarms, and errors, and each code corresponds to a specific condition or component failure. If your keypad displays E04, verify that the code is not a similar designation like ER-04 or E.04, or confirm that it matches another Yaskawa fault family. Some unverified technician sources suggest E04 may relate to a line-to-line resistance error during motor autotuning, indicating autotune results fall outside the acceptable parameter range, but this is not confirmed in official GA800 materials.

Because the GA800 manual does not list E04, you should treat this as an unidentified display or a possible entry error. Record the exact code, drive model, specification number, and serial number before proceeding. Yaskawa instructs technicians to remove the underlying cause and reset the drive after any fault or alarm. Without a verified definition, the best approach is systematic inspection of motor wiring, parameter settings, and autotune procedure, then contact Yaskawa support with your recorded information if the code persists.

Jump to Fix

Common Causes

Step-by-Step Fix

  1. Record the exact display by photographing the keypad or writing down the full alphanumeric code, including any prefix (E, ER, A) and suffix, along with the drive model, spec number, and serial number from the nameplate.
  2. Verify the code by comparing your display against the fault and alarm tables in the GA800 technical manual for your specific model and firmware revision.
  3. Inspect motor wiring by shutting off and locking out power, then checking all three motor leads (U, V, W) for tightness, corrosion, and correct termination at both the drive and motor terminal boxes.
  4. Measure motor resistance using a digital multimeter in ohms mode, comparing line-to-line resistance (U-V, V-W, W-U) to verify all three readings are balanced and match the motor’s expected values.
  5. Review motor parameters in the drive’s programming menu, confirming that rated voltage, current, frequency, and pole count match the motor nameplate exactly.
  6. Clear the fault and reset by pressing the reset button on the keypad or cycling drive power per the GA800 manual, then attempt a controlled startup or re-run autotune if applicable.
  7. Contact Yaskawa support if the code reappears or if you cannot match E04 to any documented fault, providing your recorded model, serial, and failure information for factory-level diagnosis.

Parts Often Needed

PartNotes
GA800 control board (PCB)Amazon | Replace only if Yaskawa support confirms board fault after code verification.
Cooling fan (GA800 model-specific)Amazon | GA800 maintenance manual lists fan as a replaceable component, though not linked to E04.

When to Call a Pro

Call a qualified drives technician or Yaskawa factory support if you cannot locate E04 in your GA800 manual, if motor resistance measurements are unbalanced or out of spec, or if the code returns after parameter correction and wiring inspection. Yaskawa support requires the drive model, spec number, serial number, and exact fault code to provide diagnosis. If your application involves a process that cannot tolerate extended downtime, or if you lack a calibrated multimeter and familiarity with VFD parameter programming, professional service will save time and prevent incorrect part replacement.

See Also


🔧 Need a professional? Get free quotes from certified HVAC contractors near you.
Get Free Quotes →
Share this post on:

Previous Post
Yaskawa GA800 E07 Fault - Causes & Fix
Next Post
Yaskawa GA800 E02 Fault - Causes & Fix