The Weil-McLain E10 error code means low system water pressure. On Weil-McLain gas boilers (Ultra, GV, WM97+ series), E10 fires when the system pressure sensor reads below the minimum threshold — typically below 5–10 PSI depending on the model. The boiler locks out on E10 to prevent operating the heat exchanger without adequate water flow, which would cause thermal damage. E10 is one of the most commonly searched Weil-McLain codes because the fix is usually quick and doesn’t require a service call.
| Part | Notes |
|---|---|
| Expansion tank (2–5 gallon) | Replace when bladder fails; Amtrol Extrol is a common direct replacement |
| Auto-fill valve (Watts 911) | Replace if valve is stuck open (overpressure) or stuck closed (E10 recurrence) |
| Pressure relief valve | Replace if it’s been weeping; a weeping PRV causes slow pressure loss |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If pressure drops more than 5 PSI per day after filling, you have a significant leak somewhere in the system. A plumber or boiler tech can perform a pressure isolation test to find the leak zone before water damage occurs.