The True T-23 is a one-section reach-in commercial refrigerator widely used in bars, restaurants, and foodservice operations. It is part of True’s T-series line — one of the most common commercial refrigerators in service in North America. Older T-23 models used analog temperature controls with no error codes. Newer T-23 units equipped with the True Digital Control (TDC) system display error codes on the temperature readout display when a fault is detected.
| Code | Fault |
|---|---|
| E1 | Ambient temperature sensor fault |
| E2 | Cabinet temperature sensor fault — top |
| E3 | Cabinet temperature sensor fault — bottom (where equipped) |
| E4 | Evaporator coil temperature sensor fault |
| E5 | Defrost sensor fault |
| E6 | High temperature alarm — cabinet above setpoint |
| E7 | Door open alarm — door held open beyond time limit |
| E8 | Defrost cycle timeout — defrost took too long |
| EE | Control board fault |
| Part | Notes |
|---|---|
| Cabinet temperature sensor | True part; check connector type |
| Defrost heater | Matches voltage and wattage |
| Evaporator fan motor | Shaded pole type; match CFM |
| Defrost termination thermostat | Check cutout temperature rating |
| Condenser fan motor | Bottom-mounted; check rotation |
| True Digital Control board | For EE fault; verify power supply first |
When diagnosing commercial refrigeration faults, start with the controller’s alarm history. Most digital controllers (Dixell, Carel, Eliwell) store the last 5-10 alarms with timestamps. An E1 alarm that appears consistently every few hours suggests a sensor going bad — the resistance value drifts until it’s out of range. An intermittent HI/LO alarm that appears only during hot afternoons suggests a condenser issue, not a sensor fault.
Prevention: Schedule quarterly condenser coil cleaning. Dirty coils are the #1 cause of high-head-pressure faults and compressor overheating in commercial refrigeration. Use a soft brush and compressed air — never a pressure washer on the coil fins.
Before ordering, match the refrigeration part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
True T-23 refrigerators with refrigerant undercharge require EPA 608 certified technicians for refrigerant service. If the unit is repeatedly tripping high temperature (E6) with a clean condenser and working fans, the issue may be a low refrigerant charge — a technician with manifold gauges should verify system pressures before condemning the compressor.