Temperature sensor
Common error-code part. Confirm resistance and connector style.
True Refrigeration E5 Error Code - Defrost Sensor Causes & Fix: likely causes, checks, and repair decisions before replacing parts.
True Refrigeration E5 Error Code - Defrost Sensor Causes & Fix: likely causes, checks, and repair decisions before replacing parts.
Likely parts to price
Common error-code part. Confirm resistance and connector style.
Useful to price for temperature-reading faults.
Low-cost safety part for heat and no-start symptoms.
True Refrigeration error code E5 usually points to a defrost probe or evaporator sensor fault. On reach-in coolers and freezers that use Dixell, LAE, or True-branded electronic controls, the board expects a stable temperature signal from the evaporator area during defrost and recovery. When that signal goes open, shorted, or outside the controller’s allowed range, the cabinet posts E5 and may extend defrost time, lock the compressor out, or run into a fail-safe cycle that protects the evaporator from icing up.
| Part | Notes |
|---|---|
| Defrost / evaporator temperature probe | Match the controller family and probe curve before ordering |
| Probe harness or extension lead | Useful when the original lead is cut or water-damaged |
| Defrost heater | Replace if the coil stays iced even with a good probe |
| Electronic temperature controller | Only after confirming the probe and heater circuit test good |
When diagnosing commercial refrigeration faults, start with the controller’s alarm history. Most digital controllers (Dixell, Carel, Eliwell) store the last 5-10 alarms with timestamps. An E1 alarm that appears consistently every few hours suggests a sensor going bad — the resistance value drifts until it’s out of range. An intermittent HI/LO alarm that appears only during hot afternoons suggests a condenser issue, not a sensor fault.
Prevention: Schedule quarterly condenser coil cleaning. Dirty coils are the #1 cause of high-head-pressure faults and compressor overheating in commercial refrigeration. Use a soft brush and compressed air — never a pressure washer on the coil fins.
Before ordering, match the refrigeration part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Call a commercial refrigeration tech if the coil keeps icing after probe replacement, or if you confirm the probe reads correctly and the board still throws E5. At that point you may have a controller fault or a defrost circuit problem that needs live electrical testing.