Samsung mini split indoor thermistor
Part: DB95-04544A
Match the model and connector before replacing E2-01 or E2-02 sensor parts.
Use this Samsung Mini Split Error Codes - Complete Fix Guide reference to match the code with likely causes, service checks, and repair decisions.
Use this Samsung Mini Split Error Codes - Complete Fix Guide reference to match the code with likely causes, service checks, and repair decisions.
Parts to price first
Part: DB95-04544A
Match the model and connector before replacing E2-01 or E2-02 sensor parts.
Price only after confirming E1-01 returns after full power discharge.
Part: DB27-00018A
Relevant for E9-01 drain faults after clearing the drain line and pan.
Use the installation manual gauge and rating for indoor-outdoor communication faults.
Samsung mini-splits display error codes as E-codes with two additional digits (e.g., E1-01, E3-01). The primary number indicates the fault category; the sub-number indicates the specific fault within that category. Access error codes via the indoor unit display or the Samsung SmartThings app on WiFi-enabled models.
| Code | Meaning | Quick Fix |
|---|---|---|
| E1-01 | Indoor PCB fault | Replace indoor PCB |
| E1-02 | Indoor unit communication fault | Check wiring |
| E2-01 | Indoor inlet thermistor fault | Replace thermistor |
| E2-02 | Indoor outlet thermistor fault | Replace thermistor |
| E3-01 | Outdoor PCB fault | Inspect outdoor board |
| E3-02 | Outdoor communication fault | Check outdoor wiring and fuses |
| E4-01 | High pressure protection | Clean outdoor coil |
| E4-02 | Low pressure protection | Check refrigerant charge |
| E4-03 | Discharge temperature protection | Refrigerant issue |
| E5-01 | Overcurrent protection | Check power supply; compressor |
| E5-02 | IPM overheat protection | Check cooling of outdoor board |
| E6-01 | Fan motor fault — indoor | Check indoor fan motor |
| E6-02 | Fan motor fault — outdoor | Check outdoor fan blade |
| E7-01 | Communication between indoor and outdoor | Check 3-wire signal cable |
| E9-01 | Drain float fault | Clear drain line |
The indoor control board has reported an internal fault. Before replacing the board, disconnect power for 10 minutes (full capacitor discharge) and restore. If the fault returns immediately, the PCB needs replacement. Samsung indoor boards are model-specific — order using the unit’s model number from the nameplate.
Indoor room temperature sensor or indoor coil sensor failure. On Samsung Wind-Free units, these sensors are mounted in the indoor unit chassis and accessible after removing the front panel and filter. Re-seat the thermistor connector first. Typical resistance is 5–15 kΩ depending on temperature. Replace if out of range.
High refrigerant pressure tripped the safety switch. Causes: dirty outdoor coil (most common in summer), outdoor fan not running, refrigerant overcharge, or ambient temp too high. Clean the outdoor unit coil with water and coil cleaner, rinse from inside out.
The system has lost refrigerant charge or the expansion valve is partially blocked. A technician needs to check system pressures and leak-test the system. Continuing to operate with low refrigerant charge damages the compressor.
Verify the 3-wire signal cable connections at both the indoor and outdoor terminal blocks. Samsung uses a polarity-sensitive signal wire on most models — wire 1 is ground, wire 2 is 220V neutral, wire 3 is signal/communication. Reversing wires 2 and 3 prevents communication.
The drain pan float switch activated — water level is too high. Vacuum out the drain line from the outdoor drain outlet, then clear any blockage at the drain pan inside the indoor unit. Samsung Wind-Free units use a shallow drain pan that fills quickly when the drain line is partially blocked.
| Part | Notes |
|---|---|
| Indoor thermistor | Samsung DB95-04544A or model-specific |
| Indoor PCB | Model-specific — note full model code |
| Drain float switch | Samsung DB27-00018A or compatible |
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
E4-02 (low pressure), E4-03 (discharge temp), and E5-01 (overcurrent) all indicate refrigerant system or compressor issues that require EPA-certified technician intervention.
E1-01 means the indoor PCB has reported an internal fault. Disconnect power for about 10 minutes first; if the fault returns immediately, the indoor control board is suspect.
E4-01 is high-pressure protection. Common causes are a dirty outdoor coil, outdoor fan problem, refrigerant overcharge, or very high outdoor ambient temperature.
E9-01 means the drain pan float switch activated. Clear the drain line and drain pan before replacing the float switch or control parts.