Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
What Samsung mini-split E1-01 means, why the outdoor temperature sensor faults, and how to fix it.
What Samsung mini-split E1-01 means, why the outdoor temperature sensor faults, and how to fix it.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
E1-01 on a Samsung mini-split (Wind-Free, AR series, and multi-zone systems) indicates an outdoor air temperature sensor fault. The control board is receiving a signal from the outdoor ambient temperature sensor that is outside the valid range — either an open circuit (sensor disconnected or broken) or a short circuit (sensor shorted). Samsung uses thermistor-type temperature sensors; the board compares the sensor resistance to a known curve and flags E1-01 when the reading is invalid.
| Part | Notes |
|---|---|
| Outdoor ambient temperature sensor | Samsung OEM; 10 kΩ NTC thermistor; match connector |
| Sensor harness/extension wire | If wire run is damaged |
| Outdoor control board | Only if sensor input circuit is confirmed failed on the board |
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If sensor and wiring check out but E1-01 persists, the outdoor control board’s sensor input circuit may need component-level repair or board replacement. A Samsung-authorized technician can access fault logs and confirm the board diagnosis.