Rinnai outlet temperature sensor
Part: Rinnai 100001223
Primary sensor to price first for Error Code 52.
Rinnai tankless water heater Error Code 52 means the outlet water temperature sensor has failed. Learn causes, diagnostic steps, and the fix.
Rinnai tankless water heater Error Code 52 means the outlet water temperature sensor has failed. Learn causes, diagnostic steps, and the fix.
Parts to price first
Part: Rinnai 100001223
Primary sensor to price first for Error Code 52.
Part: Rinnai 100001222
Companion sensor if the fault is confused with Error Code 53.
Error Code 52 on Rinnai tankless water heaters indicates a fault with the outlet water temperature sensor (also called the outgoing hot water thermistor). The sensor has failed or is reading an out-of-range value, causing the unit to shut down to prevent scalding or heat exchanger damage.
The outlet temperature sensor monitors the temperature of the water leaving the unit. This is the primary feedback for the modulating burner — if the sensor fails, the unit cannot regulate water temperature and shuts down safely with Error 52.
| Code | Sensor | Location |
|---|---|---|
| 52 | Outlet water temperature sensor | Outgoing hot water side |
| 53 | Inlet water temperature sensor | Incoming cold water side |
| 61 | Gas combustion fault | Not a sensor — burner issue |
| Cause | Likelihood |
|---|---|
| Failed outlet temperature sensor | Very High |
| Corroded or loose sensor connector | High |
| Damaged sensor wire (water damage, pinching) | Medium |
| Control board analog input failure | Low |
Step 1 — Locate the outlet temperature sensor
Step 2 — Check the wiring connector
Step 3 — Measure sensor resistance Rinnai outlet temperature sensors are NTC thermistors:
Step 4 — Compare to a reference
Step 5 — Check the control board
| Part | Notes |
|---|---|
| Outlet temperature sensor | Rinnai part 100001223 or model-specific equivalent |
| Inlet temperature sensor (if confused with 53) | Rinnai part 100001222 |
| Control board | Last resort — verify sensor and wiring first |
Before ordering, match the water-heating part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Note: Rinnai Error 52 and Error 53 are often confused. Error 52 = outlet (hot water leaving the unit); Error 53 = inlet (cold water entering the unit). Both are fixed the same way — replace the failed sensor.