Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Use this Rheem RPH Series Packaged Unit Error Codes reference to match the code with likely causes, service checks, and repair decisions.
Use this Rheem RPH Series Packaged Unit Error Codes reference to match the code with likely causes, service checks, and repair decisions.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Rheem RPH packaged heat pump units use an LED diagnostic indicator on the control board. Flash sequences indicate specific faults - count flashes between 3-second pauses. Units with the EcoNet communicating system display alphanumeric codes on the thermostat.
| Flashes | Fault Description | Common Cause | Action |
|---|---|---|---|
| 2 | Low-pressure lockout | Low charge or frozen coil | Check refrigerant charge |
| 3 | High-pressure lockout | Dirty coil or failed fan | Wash condenser coil |
| 4 | Open high-pressure switch | Overcharge or condenser blockage | Check subcooling |
| 5 | Open low-pressure switch | Low refrigerant, TXV issue | Inspect TXV and charge level |
| 6 | Outdoor fan motor fault | Failed motor or run capacitor | Check capacitor and motor amps |
| 7 | Defrost fault | Defrost sensor or board failure | Check sensor clip and board |
| 8 | Reversing valve stuck | Mechanical or solenoid failure | Check 24 VAC to solenoid |
| 9 | Control board failure | Internal failure | Replace control board |
| Steady ON | Normal operation or continuity | No active fault | N/A |
Most common summer service call on packaged units. Verify condenser fan rotation (should pull air up through the coil). Wash coil with commercial coil cleaner. Check for restricted condenser fan discharge.
In cooling mode: check refrigerant charge using subcooling method. In heating mode: ice on outdoor coil triggers LP trip - verify defrost system operation.
Confirm defrost thermostat is clipped firmly to the liquid line near the outdoor coil. Check defrost board timing pins - jumper JP1 sets cycle time. Verify defrost terminates within 14 minutes.
Rheem RPH reversing valves are energized in cooling. If stuck in one position, you’ll have cooling-only or heating-only operation. Measure solenoid coil resistance (typically 18-30 ohm).
| Part | Notes |
|---|---|
| Defrost board | Critical - match to exact model |
| Defrost thermostat | Available in multiple trip temperatures |
| Run capacitor | Dual-run - test both sections |
| Reversing valve | Match tonnage and refrigerant type |
| Contactor | Check for pitting and coil voltage |
| Control board | Match unit serial and model number |
Heat-pump, rooftop, and air-conditioner faults usually come from airflow, condensate drainage, outdoor coil condition, defrost sensors, pressure switches, capacitors/contactors, or low-voltage communication. Check filters, coils, drains, disconnect power, and thermostat wiring before assuming the compressor or board has failed.
DIY vs Pro: Filter, coil, drain, and visual wiring checks are reasonable owner tasks. Refrigerant diagnostics, capacitor testing, contactor replacement, and compressor or control-board work should be done by an HVAC technician.
Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
Pro tip: Rheem RPH units with EcoNet log fault history with timestamps. Connect EcoNet app to retrieve detailed fault history before servicing - saves significant diagnostic time.