Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
What Rheem 3 flashes means on a furnace, why the draft pressure switch faults, and how to fix it.
What Rheem 3 flashes means on a furnace, why the draft pressure switch faults, and how to fix it.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Three flashes on a Rheem furnace diagnostic LED signals a pressure switch fault — specifically, the draft pressure switch failed to close within the expected time after the induced draft motor started. The pressure switch monitors that the inducer is pulling adequate combustion airflow through the heat exchanger before the gas valve is allowed to open. When the switch stays open, the board blocks ignition as a safety measure.
| Part | Notes |
|---|---|
| Draft pressure switch | Match Rheem part number; pressure rating varies by model |
| Pressure switch hose | Standard 1/4” ID silicone or rubber tubing |
| Inducer motor capacitor | Test before replacing the full motor assembly |
| Induced draft motor | Replace if capacitor checks good but motor is slow or noisy |
Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.
DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the flue is clear, pressure switch and hose are intact, and the inducer motor runs at speed but the switch still won’t close, have a licensed HVAC technician check for a failed heat exchanger or incorrect pressure switch calibration — both require specialized tools to diagnose safely.