Rheem RA13 Air Conditioner Error Codes

⚡ Quick Answer

Rheem RA13 guide for high-pressure, low-pressure, compressor overload, control-board, thermistor, anti-short-cycle, and low-voltage faults.

⚡ AT A GLANCEScroll down for full repair guide
What it meansRheem RA13 guide for high-pressure, low-pressure, compressor overload, control-board, thermistor, anti-short-cycle, and low-voltage faults.
Most likely causeMost hvac faults come from power, airflow, sensor, drain, ignition, or control-board conditions. Start with the lowest-risk checks before replacing parts.
First checkConfirm the exact code, power-cycle once, inspect the obvious safety/flow path, then follow the step-by-step checks below.
⏱Repair time10-45 minutes for basic checks
🔧Part neededRun capacitor
Repair intent

Need this fixed instead of diagnosed?

Rheem RA13 guide for high-pressure, low-pressure, compressor overload, control-board, thermistor, anti-short-cycle, and low-voltage faults.

Likely parts to price

Price the common parts before you book service.

Run capacitor

Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.

Flame sensor

Price this first on furnace ignition faults after cleaning and safety checks.

Igniter

Common furnace start failure part. Confirm connector and model compatibility.

Control board

Higher-cost part to price only after power, sensor, and wiring checks.

Rheem RA13 Air Conditioner Error Codes — What They Mean

The Rheem RA13 (and its Ruud counterpart, the RA13) is a 13–14 SEER single-stage central air conditioner using R-410A refrigerant. It is designed for replacement and new construction applications where budget is the primary constraint. The RA13 uses a conventional control board with a status LED to communicate faults via flash codes. These units do not have a communicating bus — they operate in a standard thermostat-controlled on/off mode.

Jump to Fix

Rheem RA13 LED Flash Code Reference

Flash SequenceFault
1 flashNormal — standby
2 flashesHigh-pressure switch open
3 flashesLow-pressure switch open
4 flashesCompressor protection device open
5 flashesControl board fault
6 flashesThermistor fault — outdoor sensor
7 flashesAnti-short cycle lockout (5-minute delay)
Rapid continuousLow voltage — below 18VAC

Common Causes by Code

Step-by-Step Fix

  1. Locate the status LED — Remove the electrical access panel on the RA13 outdoor unit. The control board is mounted on the inside of the panel or on a bracket near the compressor compartment. The LED will be flashing the fault code.
  2. For 2 flashes (high pressure) — Turn off the unit at the thermostat. Inspect the condenser coil from the outside — look for dirt buildup at the base (ground level) where debris collects. Also check the fan motor: grab the blade (with power off) and check for rough bearing feel. Test the run capacitor with a capacitor meter.
  3. For 3 flashes (low pressure) — Connect R-410A manifold gauges to the service ports. Record static pressure (unit off) and operating pressures (unit running). If suction is below 70 PSIG with the unit running at 70°F ambient, charge is significantly low — find the leak.
  4. For 4 flashes (compressor protection) — Power cycle after a 30-minute wait. Measure supply voltage at the disconnect — both legs at the same time to confirm voltage is balanced. Unbalanced voltage (more than 2% difference between legs) causes compressor overheating.
  5. Rapid flash (low voltage) — Measure R-to-C voltage at the control board terminals. If below 18VAC, check the 40VA or 75VA transformer. Also verify no shorted control devices are dragging down the 24V circuit (disconnect the G, Y, W terminals one at a time to isolate).

Parts Often Needed

PartNotes
Dual run capacitorMost common RA13 failure; affects both fan and compressor
Contactor2-pole; inspect for pitting and carbon buildup
High-pressure switchSpade terminals; replaces easily
Low-pressure switch50 PSIG cutout for R-410A
Control boardCheck fuse first before ordering board
Condenser fan motorMatch RPM, HP, and shaft size

Technician Tips

Heat-pump, rooftop, and air-conditioner faults usually come from airflow, condensate drainage, outdoor coil condition, defrost sensors, pressure switches, capacitors/contactors, or low-voltage communication. Check filters, coils, drains, disconnect power, and thermostat wiring before assuming the compressor or board has failed.

DIY vs Pro: Filter, coil, drain, and visual wiring checks are reasonable owner tasks. Refrigerant diagnostics, capacitor testing, contactor replacement, and compressor or control-board work should be done by an HVAC technician.

Need Replacement Parts?

Before ordering, match the HVAC part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.

When to Call a Pro

Refrigerant handling on the RA13 requires EPA 608 certification. If the compressor draws high amperage (above nameplate FLA) but produces no cooling, the compressor may be mechanically failed — a technician with a clamp-on ammeter and manifold gauges can confirm this before an expensive replacement decision is made.


Need a professional? Compare HVAC repair options before replacing parts.
Compare Repair Options