Run capacitor
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Diagnose Rheem Furnace Error Code 57 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Diagnose Rheem Furnace Error Code 57 - Causes & Fix: likely causes to check, measurements to verify, and repair decisions before parts replacement.
Likely parts to price
Common no-start and weak-compressor failure point. Match the microfarad and voltage rating.
Price this first on furnace ignition faults after cleaning and safety checks.
Common furnace start failure part. Confirm connector and model compatibility.
Higher-cost part to price only after power, sensor, and wiring checks.
Rheem furnace error code 57 indicates a low-stage pressure switch fault — specifically, the low-stage pressure switch failed to close (or opened unexpectedly) during the call for heat. On two-stage Rheem furnaces, the inducer motor runs at low speed first and the low-stage pressure switch must close to confirm adequate draft before ignition. Code 57 means the control board saw the switch remain open when it should be closed, aborting the ignition sequence. The furnace will lockout after repeated failed attempts.
| Part | Notes |
|---|---|
| Low-stage pressure switch | Match to exact model; Rheem/Ruud switches are model-specific |
| Pressure switch hose | Available at HVAC supply houses; measure ID/OD before ordering |
| Inducer motor assembly | Replace if motor is seized, humming, or capacitor has failed |
| Condensate drain trap | Clean or replace if blocked, which causes pressure switch issues |
Modern furnaces use LED flash codes on the control board to diagnose failures. Before calling for service, count the number of flashes between pauses and check your owner’s manual for the code chart. The most common furnace error — 1-4 flashes usually means ignition failure — is often caused by a dirty flame sensor. The flame sensor is a $15-30 part that takes 10 minutes to clean. Remove it with a 1/4” nut driver, gently scrub the metal rod with emery cloth or a dollar bill (yes, a dollar bill — it’s the right abrasiveness), and reinstall. This fixes about 60% of “no heat” service calls.
DIY vs Pro: Error codes related to pressure switches (usually 2-3 flashes) often indicate blocked vents or condensate drains — safe to check yourself. Codes related to gas valves or ignition modules (4+ flashes) are best left to a licensed HVAC technician.
Before ordering, match the furnace part to the model number, electrical rating, and failure symptom. Check current prices on Amazon - prices and availability change frequently.
If the inducer runs at full speed, the hose is clear, and a new pressure switch still gives code 57, the flue vent may be partially blocked or the heat exchanger may have a crack affecting combustion airflow. Both require a tech with combustion analyzer and inspection camera.